English
Language : 

X96010 Datasheet, PDF (6/26 Pages) Intersil Corporation – Sensor Conditioner with Dual Look Up Table Memory and DACs
X96010
A/D CONVERTER CHARACTERISTICS (See pg. 4 for Standard Conditions)
Symbol
Parameter
Min
ADCTIME
A/D converter conversion
time
RINADC
VSense pin input
100
resistance
CINADC
VSense pin input
1
capacitance
VINADC
VSense input signal range
0
The ADC is monotonic
OffsetADC
FSErrorADC
DNLADC
A/D converter offset error
A/D converter full scale error
A/D Converter Differential
Nonlinearity
INLADC
A/D converter Integral
Nonlinearity
Typ
Max Unit
Test Conditions / Notes
9
ms Proportional to A/D converter
input voltage. This value is
maximum at full scale input
of A/D converter.
ADCfiltOff = “1”
kΩ VSense as an input,
ADCIN bit = “1”
7
pF VSense as an input,
ADCIN bit = “1”,
Frequency = 1 MHz
See note 3.
V(VRef) V This is the A/D Converter
Dynamic Range. ADCIN bit = “1”
±1
LSB See notes 1 and 2
±1
LSB
±0.5
LSB
±1
LSB
Notes: 1. “LSB” is defined as V(VRef)/255, “Full Scale” is defined as V(VRef).
[ ] 2. OffsetADC: For an ideal converter, the first transition of its transfer curve occurs at
amount of deviation between the measured first transition point and the ideal point.
0.5 x V(VRef)
255
above zero. Offset error is the
[ ] FSErrorADC: For an ideal converter, the last transition of its transfer curve occurs at
amount of deviation between the measured last transition point and the ideal point,
254.5 x V(VRef)
255
. Full Scale Error is the
after subtracting the Offset from the measured curve.
DNLADC: DNL is defined as the difference between the ideal and the measured code transitions for successive A/D code outputs
expressed in LSBs. The measured transfer curve is adjusted for Offset and Fullscale errors before calculating DNL.
INLADC: The deviation of the measured transfer function of an A/D converter from the ideal transfer function. The INL error is also
defined as the sum of the DNL errors starting from code 00h to the code where the INL measurement is desired. The measured trans-
fer curve is adjusted for Offset and Fullscale errors before calculating INL.
3. These parameters are periodically sampled and not 100% tested.
6
FN8214.1
October 25, 2005