English
Language : 

X80140 Datasheet, PDF (6/18 Pages) Intersil Corporation – Voltage Supervisor/Sequencer Quad Programmable Time Delay with Local/Remote Voltage Monitors
X80140, X80141, X80142, X80143, X80144
Serial Interface Over the recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
DC CHARACTERISTICS
ICC1
ILI
ILO
Active Supply Current (VCC) Read or Write
to Memory or registers
Input Leakage Current (SCL, WP, A0, A1)
Output Leakage Current (SDA)
VIL = VCC x 0.1
VIH = VCC x 0.9,
fSCL = 400kHz
VIL = GND to VCC
VSDA = GND to VCC
Device is in Standby
2.5
mA
15
µA
15
µA
VIL
VIH
VHYS
Input LOW Voltage (SDA, SCL, WP, A0, A1)
Input HIGH Voltage (SDA, SCL, WP, A0, A1)
Schmidt Trigger Input Hysteresis
Fixed input level
-0.5
VCC x 0.7
0.2
VCC x 0.3
V
5.5
V
V
VCC related level
VOL
Output LOW Voltage (SDA)
IOL = 4.0mA
AC CHARACTERISTICS
0.05 x 5
V
0.4
V
fSCL
SCL Clock Frequency
tIN
Pulse width Suppression Time at inputs
tAA (Note 1) SCL LOW to SDA Data Out Valid
tBUF (Note 1) Time the bus is free before start of new
transmission
400
kHz
50
ns
0.1
1.5
µs
1.3
µs
tLOW
Clock LOW Time
tHIGH
Clock HIGH Time
tSU:STA Start Condition Setup Time
tHD:STA Start Condition Hold Time
tSU:DAT Data In Setup Time
tHD:DAT Data In Hold Time
tSU:STO Stop Condition Setup Time
tHD:STO Stop Condition Hold Time
tDH (Note 1) Data Output Hold Time
tR (Note 1) SDA and SCL Rise Time
tF (Note 1) SDA and SCL Fall Time
tSU:WP WP Setup Time
tHD:WP WP Hold Time
tSU:ADR A0, A1 Setup Time
tHD:ADR A0, A1 Hold Time
tSU:VP VP Setup Time
Cb (Note 3) Capacitive load for each bus line
1.3
0.6
0.6
0.6
100
0
0.6
0.6
50
20 +.1Cb
20 +.1Cb
0.6
0
0.6
0
0.6
µs
µs
µs
µs
ns
µs
µs
µs
ns
300
ns
300
ns
µs
µs
µs
µs
µs
400
pF
tWC (Note 2) EEPROM Write Cycle Time
5
10
ms
NOTES:
1. This parameter is based on characterization data.
2. tWC is the time from a valid stop condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle. It is the
minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used.
3. This parameter is not 100% tested.
6
FN8153.0
January 20, 2005