English
Language : 

X40030_13 Datasheet, PDF (16/23 Pages) Intersil Corporation – Triple Voltage Monitor with Integrated CPU Supervisor
X40030, X40031, X40034, X40035
DC Operating Characteristics Over the recommended operating conditions, unless otherwise specified. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
(Note 3) (Note 7) (Note 3) UNIT
VTRIP2 V2MON Trip Point Voltage Range
(Note 8)
X40030, X40031
X40034, X40035
1.7
4.75
V
0.9
3.5
V
X40030, X40031-A
2.85
2.9
2.95
V
X40030, X40031-B
2.55
2.6
2.65
V
X40030, X40031-C
2.15
2.2
2.25
V
X40034, X40035-A and B
1.25
1.3
1.35
V
X40034, X40035-C
0.95
1.0
1.05
V
tRPD2 VTRIP2 to V2FAIL
(Note 9)
5
µs
THIRD SUPPLY MONITOR
IV3
VTRIP3
(Note 8)
V3MON Current
V3MON Trip Point Voltage Range
X40030, X40031
15
µA
1.7
4.75
V
1.65
1.7
1.75
V
X40034, X40035-A
3.05
3.1
3.15
V
X40034, X40035-B and C
2.85
2.9
2.95
V
tRPD3 VTRIP3 to V3FAIL
(Note 9)
5
µs
NOTES:
4. The device enters the Active state after any start, and remains active until: 9 clock cycles later if the Device Select Bits in the Slave Address
Byte are incorrect; 200ns after a stop ending a read operation; or tWC after a stop ending a write operation.
5. The device goes into Standby: 200ns after any stop, except those that initiate a high voltage write cycle; tWC after a stop that initiates a high
voltage cycle; or 9 clock cycles after any start that is not followed by the correct Device Select Bits in the Slave Address Byte.
6. VIL Min. and VIH Max. are for reference only and are not tested.
7. At +25°C, VCC = 3V
8. See ordering information for standard programming levels. For custom programmed levels, contact factory.
9. Based on characterization data.
Equivalent Input Circuit for VxMON (x = 1, 2, 3)
R
ΔV
Vref
VxMON
+
C
VREF
–
OUTPUT PIN
ΔV = 100mV
Capacitance
tRPDX = 5µs WORST CASE
SYMBOL
COUT
CIN
PARAMETER
Output Capacitance (SDA, RESET/RESET, LOWLINE, V2FAIL,V3FAIL, WDO)
Input Capacitance (SCL, WP, MR)
TEST CONDITIONS
VOUT = 0V
VIN = 0V
MAX
(Note 3)
8
6
UNIT
pF
pF
16
FN8114.2