English
Language : 

X40030_13 Datasheet, PDF (15/23 Pages) Intersil Corporation – Triple Voltage Monitor with Integrated CPU Supervisor
X40030, X40031, X40034, X40035
Absolute Maximum Ratings
Temperature Under Bias . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage on any Pin with respect to VSS . . . . . . . . . . . . . -1.0V to +7V
DC Output Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5mA
Chip Supply Voltage
X40030, X40031. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
X40034, X40035. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
Monitored Voltage
X40030, X40031. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.7V to 5.5V
X40034, X40035. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0V to 5.5V
Thermal Information
Pb-free reflow profile . . . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
Operating Conditions
Commercial Temperature Range. . . . . . . . . . . . . . . . . 0°C to +75°C
Industrial Temperature Range . . . . . . . . . . . . . . . . . .-40°C to +85°C
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
NOTE:
3. Parts are 100% tested at +25°C. Temperature limits established by characterization and are not production tested.
DC Operating Characteristics Over the recommended operating conditions, unless otherwise specified.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
(Note 3) (Note 7) (Note 3) UNIT
ICC1
(Note 4)
ICC2
(Note 4)
Active Supply Current (VCC) Read
Active Supply Current (VCC) Write
VIL = VCC x 0.1, VIH = VCC x 0.9,
fSCL = 400kHz
1.5
mA
3.0
mA
ISB1
(Note 4)
ISB2
(Note 5)
ILI
ILO
Standby Current (VCC) AC (WDT off)
VIL = VCC x 0.1
VIH = VCC x 0.9
fSCL, fSDA = 400kHz
Standby Current (VCC) DC (WDT on)
VSDA = VSCL = VCC
Others = GND or VCC
Input Leakage Current (SCL, MR, WP)
VIL = GND to VCC
Output Leakage Current (SDA, V2FAIL, V3FAIL, WDO, VSDA = GND to VCC
RESET)
Device is in Standby (Note 5)
6
10
µA
25
30
µA
10
µA
10
µA
VIL
Input LOW Voltage (SDA, SCL, MR, WP)
(Note 6)
-0.5
VCC x 0.3 V
VIH
Input HIGH Voltage (SDA, SCL, MR, WP)
(Note 6)
VCC x 0.7
VCC + 0.5 V
VHYS Schmitt Trigger Input Hysteresis
(Note 9)
Fixed Input Level
0.2
V
VCC Related Level
0.05 x VCC
VOL
Output LOW Voltage (SDA, RESET/RESET, LOWLINE, IOL = 3.0mA (2.7V to 5.5V)
V2FAIL, V3FAIL, WDO)
IOL = 1.8mA (2.7V to 3.6V)
VOH Output (RESET, LOWLINE) HIGH Voltage
IOH = -1.0mA (2.7V to 5.5V)
VCC – 0.8
IOH = -0.4mA (2.7V to 3.6V)
VCC – 0.4
VCC SUPPLY
VTRIP1 VCC Trip Point Voltage Range
(Note 8)
2.0
X40030, X40031-A, X40034,
4.55
4.6
X40035
V
0.4
V
V
4.75
V
4.65
V
X40030, X40031-B
4.35
4.4
4.45
V
X40030, X40031-C
2.85
2.9
2.95
V
SECOND SUPPLY MONITOR
IV2
V2MON Current
15
µA
15
FN8114.2
August 25, 2008