English
Language : 

X9440 Datasheet, PDF (12/21 Pages) Intersil Corporation – Mixed Signal with SPI Interface
X9440
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
Parameter
ICC1 VCC supply current (active)
ICC2 VCC supply current (nonvolatile
write)
ISB
VCC current (standby)
ILI
Input leakage current
ILO
Output leakage current
VIH
Input HIGH voltage
VIL
Input LOW voltage
VOL Output LOW voltage
Min.
VCC x 0.7
-0.5
Limits
Typ. Max. Unit
Test Conditions
400
µA fSCK = 2MHz, SO = Open,
Other Inputs = VSS
1
mA fSCK = 2MHz, SO = Open,
Other Inputs = VSS
1
µA SCK = SI = VSS, Addr. = VSS
10
µA VIN = VSS to VCC
10
µA VOUT = VSS to VCC
VCC + 0.5 V
VCC x 0.1 V
0.4
V IOL = 3mA
ENDURANCE AND DATA RETENTION
Parameter
Minimum endurance
Data retention
Min.
100,000
100
Unit
Data changes per bit per register
Years
CAPACITANCE
Symbol
CI/O
CIN
CL, CH, CW
Test
Output capacitance (SO)
Input capacitance (A0, A1, SI, and SCK)
Potentiometer capacitance
Max.
8
6
10/10/25
POWER-UP SEQUENCE
Power-up Sequence(1): (1) VCC (2) V+ and V-
Power-down Sequence: no limitation
{V+ ≤ VCC at all times}
Unit
pF
pF
pF
Test Conditions
VOUT = 0V
VIN = 0V
A.C. TEST CONDITIONS
Input pulse levels
Input rise and fall times
VCC x 0.1 to VCC x 0.9
10ns
Input and output timing level VCC x 0.5
Note: (1) Applicable to recall and power consumption applica-
tions
EQUIVALENT A.C. LOAD CIRCUIT
SDA Output
5V
1533Ω
100pF
2.7V
100pF
12
FN8200.0
March 28, 2005