English
Language : 

XC164CS Datasheet, PDF (49/71 Pages) Infineon Technologies AG – 16-Bit Single-Chip Microcontroller
XC164
Derivatives
Electrical Parameters
4.3
Operating Conditions
The following operating conditions must not be exceeded to ensure correct operation of
the XC164. All parameters specified in the following sections refer to these operating
conditions, unless otherwise noticed.
Table 11 Operating Condition Parameters
Parameter
Symbol
Limit Values
Unit Notes
min.
max.
Digital supply voltage for VDDI
the core
Digital supply voltage for VDDP
IO pads
Supply Voltage Difference ∆VDD
Digital ground voltage
VSS
Overload current
IOV
2.35
4.4
-0.5
-5
-2
Overload current coupling KOVA –
factor for analog inputs6)
–
Overload current coupling KOVD –
factor for digital I/O pins6)
–
Absolute sum of overload Σ|IOV| –
currents
2.7
V Active mode,
fCPU = fCPUmax1)
5.5
V Active mode2)
–
V
0
V
5
mA
5
mA
1.0 × 10-4 –
1.5 × 10-3 –
5.0 × 10-3 –
1.0 × 10-2 –
50
mA
VDDP - VDDI3)
Reference voltage
Per IO pin4)5)
Per analog input
pin4)5)
IOV > 0
IOV < 0
IOV > 0
IOV < 0
5)
External Load
Capacitance
CL
–
50
pF Pin drivers in
default mode7)
Ambient temperature
TA
0
70
-40
85
° C SAB-XC164 …
° C SAF-XC164 …
-40
125
° C SAK-XC164 …
1) fCPUmax = 40 MHz for devices marked …40F, fCPUmax = 20 MHz for devices marked …20F.
2) External circuitry must guarantee low level at the RSTIN pin at least until both power supply voltages have
reached the operating level.
3) This limitation must be fulfilled under all operating conditions including power-ramp-up, power-ramp-down, and
power-save modes.
Data Sheet
45
V2.1, 2003-06