English
Language : 

TDA7210V_10 Datasheet, PDF (31/44 Pages) Infineon Technologies AG – ASK/FSK Single Conversion Receiver
TDA7210V
Electrical Characteristics
4.1.3
AC/DC Characteristics at TAMB = 25°C
AC/DC characteristics involve the spread of values guaranteed within the specified voltage and ambient
temperature range. Typical characteristics are the median of the production. Currents flowing into the device are
denoted as positive currents and vice versa. The device performance parameters marked with ■ are not subject
to production test. They were verified by design/characterization.
Table 10 AC/DC Characteristics with TAMB = 25 °C, VCC = 4.5 ... 5.5 V
Parameter
Symbol
Values
Unit Note / Test Condition
Min. Typ. Max.
Test Num
ber
Supply - Supply Current
Supply Current
Standby Mode
IS PDWN –
50
100 nA Pin 27 (PDWN) open or
3.1
tied to 0 V
Supply Current
Device operating in
ISF 868
5.1
5.9
6.7
mA Pin 9 (FSEL) tied to GND,
3.2
Pin 14 (MSEL) tied to
868 MHz range, FSK mode
GND
Supply Current
Device operating in
ISF 434
4.9
5.7
6.5
mA Pin 9 (FSEL) open, Pin 14
3.3
(MSEL) tied to GND
434 MHz range, FSK mode
Supply Current
Device operating in
ISA 868
4.4
5.2
6
mA Pin 9 (FSEL) tied to GND,
3.4
Pin 14 (MSEL) open
868 MHz range, ASK mode
Supply Current
Device operating in
ISA 434
4.2
5
5.8
mA Pin 9 (FSEL) open, Pin 14
3.5
(MSEL) open
434 MHz range, ASK mode
LNA - Signal Input LNI (PIN 1), VTHRES > 2.8 V, high gain mode
Average Power Level
RFin
–
at BER = 2E-3 (Sensitivity)
-112 –
dBm Manchester encoded
■
datarate 4 kBit, 280 kHz
ASK fRF=434 MHz
IF Bandwidth
Average Power Level
RFin
–
at BER = 2E-3 (Sensitivity)
-108 –
dBm Manchester enc. datarate ■
4 kBit, 280 kHz IF
FSK fRF=434 MHz
Bandw.,± 50 kHz pk. dev.
Average Power Level
RFin
–
at BER = 2E-3 (Sensitivity)
-108 –
dBm Manchester encoded
■
datarate 4 kBit, 280 kHz
ASK fRF=868 MHz
IF Bandwidth
Average Power Level
RFin
–
at BER = 2E-3 (Sensitivity)
-107 –
dBm Manchester enc. datarate ■
4 kBit, 280 kHz IF
FSK fRF=868 MHz
Bandw.,± 50 kHz pk. dev
Average Power Level
RFin
–
at BER = 2E-3 (Sensitivity)
-115 –
dBm Manchester encoded
■
datarate 1 kBit, 280 kHz
ASK fRF=434 MHz
IF Bandwidth
Average Power Level
RFin
–
at BER = 2E-3 (Sensitivity)
-112 –
dBm Manchester enc. datarate ■
1 kBit, 280 kHz IF
FSK fRF=434 MHz
Bandw.,± 50 kHz pk. dev.
Average Power Level
RFin
–
at BER = 2E-3 (Sensitivity)
-111 –
dBm Manchester encoded
■
datarate 1 kBit, 280 kHz
ASK fRF=868 MHz
IF Bandwidth
3.6
3.7
3.8
3.9
3.10
3.11
3.12
Data Sheet
31