English
Language : 

TLE5011_11 Datasheet, PDF (29/45 Pages) Infineon Technologies AG – GMR Angle Sensor
TLE5011
Specification
Y_L
Addr: 03H
Reset Value: 00H
7
6
5
4
3
2
1
0
Y Low Byte
RU
Y_H
Addr: 04H
Reset Value: 00H
7
6
5
4
3
2
1
0
Y High Byte
RU
FCNT_STAT
Addr: 05H
Reset Value: 80H
7
6
5
4
3
2
1
0
reserved STAT_VR GMR_OFF UPDATE
FCNT
-
RS
RU
RS
RU
Field
Bits
Type Description
reserved
7
-
STAT_VR
6
RS
Voltage Regulator Status
This bit is a logical OR combination of Digital, Analog, GMR and
VDD_OV Comparator and GND_OFF, and VDD_OFF Comparator
outputs.
0: Voltage Supply OK
1: Voltage Supply is not OK
GMR_OFF
5
RU
ADC Values are no GMR values
(e.g.: Temperature measurement is active)
This bit indicates whether or not GMR values or any other values are
connected to the ADCs. This value is read back from the multiplexer
control signals.
0: X,Y Values are GMR values
1: X,Y Values normally represent temperature measurement or angle
test values. In the case of non-functional MUX, this bit is set to 1
UPDATE
4
RU
Update Toggle bit. This bit toggles after every update (update command
or automatic update at angle test)
The bit is independent of UR bit in CTRL1
FCNT
3-0
RU
Frame Counter (4-bit unsigned integer value)
This counter counts every new X,Y value pair coming out of the data
path. (approx. 80µs)
This counter is reset to 0H after any write to FSYNC and after every
change of the ANGT_EN bit. As tsettle time has to elapse for valid X,Y
data, this counter must be ≥ 2H to indicate valid X,Y values. If it
overflows, it resets to 3H to show that values are still valid.
Note: If FIR_BYP is activated, this counter counts four times faster!
Final Data Sheet
29
V2.0, 2011-03