3.6.3 GMR Parameters after Calibration
After calibration under the conditions specified in Table 9 “GMR test calibration conditions at IFX” on Page 19,
the sensor has a remaining error as shown in Table 10.
The error value refers to BZ = 0 mT and operating conditions given in Table 3 “Operating Range” on Page 14.
Table 10 GMR Parameter with Temperature-Dependent Offset Compensation
Parameter
Symbol
Limit Values
min. typ.1)
max.
Unit Notes
Overall Angle Error
αerr
-
0.7
1.6
°
Including temperature drift
2) 3)
-
-
2.2
°
1) At 25°C, B=30mT
2) Including hysteresis error
3) At 0h
4) Not subject to production test - verified by design/characterization
Including lifetime and
temperature drift 2) 4)
3.7
Signal Processing
Table 11 Signal Processing
Parameter
Symbol
Limit Values
min.
typ.1)
max.
Unit Notes
Internal Cutoff
Frequency (-3dB)
fCut-Off
-
of sin or cos Value
4.9
-
19.6
kHz FIR_BYP=0
FIR_BYP=1
Update Time of
tupd
-
sin or cos Value2)
81.9
-
µs
FIR_BYP=0
Settle Time 3)
-
tsettle
-
-
20.5
-
163.8
-
41.0
-
FIR_BYP=1
FIR_BYP=0
FIR_BYP=1
Peak ADC Output value ADCPk
-
-
23230
digits Signed 16-bit integer
(2s complement) 4) 5) 6)
1) For 4-MhHz input frequency
2) tupd = 8192 / (25 x fCLK) for FIR_BYP = 0
tupd = 8192 / (100 x fCLK) for FIR_BYP = 1
3) tsettle = 2 x tupd , after change of ADC input source
4) Output values are valid up to this limit. Above it, corrupted results may occur due to non-linearity of the ADC.
5) One digit typically represents 5.166 µV
6) Corresponds to max. GMR output value
Final Data Sheet
21
V2.0, 2011-03