English
Language : 

TLE8209-2SA Datasheet, PDF (23/38 Pages) Infineon Technologies AG – SPI Programmable H-Bridge
TLE8209-2SA
Protection and Monitoring
Electrical Characteristics: Protection and Monitoring
VS = 5 V to 28 V; VDD = 5.0 V, Tj = -40 °C to 150 °C, all voltages with respect to ground, positive current flowing
into pin (unless otherwise specified)
Pos. Parameter
Symbol
Limit Values
Unit Test Conditions
Min. Typ. Max.
Short Circuit Detection Timing
8.10.28 Delay time for fault
detection
tDF_H, tDF_L 1
2
5
µs –
8.10.29 Time from detected fault to tDF_OFF
–
–
4
high impedance of output1)
8.10.30 Delay time between
tDF_del
switching off of the output
5
17 40
stages in short circuit
µs –
µs –
Open Load
8.10.31 Open Load Diagnostic
tOL_DIAG
60
–
135
µs –
Filter Time1)
8.10.32 Low Diagnosis Threshold Vref_L
0.4 * 0.4 * 0.4 * VDD V –
VDD - VDD + 0.2
0.2
8.10.33 High Diagnosis Threshold Vref_H
0.8 * 0.8 * 0.8 * VDD V –
VDD - VDD + 0.2
0.2
8.10.34 Diagnosis Bias Voltage Vref_M
0.6 * 0.6 * 0.6 * VDD V –
VDD - VDD + 0.2
0.2
8.10.35
8.10.36
8.10.37
8.10.38
8.10.39
Positive Diagnostic Current IDIA_P
(pull down current source)
Negative Diagnostic
Current
IDIA_N
Ratio of current sources
(Pos/Neg)
RatioI_DIA
300
270
-350
-350
2
620
610
-240
-210
2.9
980
980
-100
-80
4
µA VOUTx = 14 V
µA VOUTx = Vref_H
µA VOUTx = 0 V
µA VOUTx = Vref_L
––
Undervoltage
8.10.40
8.10.41
Undervoltage at VS
VS Undervoltage Detection
Filter Time1)
VUV OFF
VUV ON
VUV HY
tUV
3.1 3.7 4.4
3.3 3.9 4.6
100 200 400
–
–
1.5
V Switch off threshold
V Switch on threshold
mV Hysteresis
µs
1) Not subject to production test; specified by design.