English
Language : 

TLE7809G Datasheet, PDF (23/52 Pages) Infineon Technologies AG – Integrated double low-side switch, high-side/LED driver, hall supply, wake-up inputs and LIN communication with embedded MCU (16kB Flash)
TLE7809G
SPI (Serial Peripheral Interface)
Table 9 SPI Output Data (cont’d)
Pos. Output Data1)
14
Supply Output (OC / OT)
Output Data after Wake-up2)
Supply Output (OC / OT)
15
VS UV5) [only “SBC Active Mode”]
“low”
1) “1” = ON / enable, “0” = OFF / disable, OC = overcurrent, UV = undervoltage,
OT = overtemperature (temp. shut-down)
2) “1” = ON, “0” = OFF, OC = overcurrent, UV = undervoltage, OT = overtemperature (temp. shut-down)
3) Becomes valid after start-up time for voltage monitoring
4) Voltage monitoring not active in SBC Standby Mode
5) This bit needs to be read twice to indicate an undervoltage condition (only for VS ramping down - bit15 set to “1”)
Table 10 Diagnostic, Protection and Safety Functions
Module
Function
Window Watchdog WD1) Failure
LDO (VReg)
OC2) at VCC
voltage regulator
UV condition
(VS related)
VCC-UV
Effect
Reset; see Table 11 “Reset
Behavior SBC” on Page 25
current limitation
Reset, see Table 11 “Reset
Behavior SBC” on Page 25
Reset, see Table 11 “Reset
Behavior SBC” on Page 25
Concept
SPI status latched until
next read-out
–
Condition occurs at VS
below operating range
–
WD current threshold
(Stop Mode)
OT3)
WD only disabled if
VCC-current < threshold and
WD not enabled via SPI
WD enabled if
VCC-current > threshold
VCC-shutdown, Reset as soon as automatically enabled with
VCC falls below reset threshold, see thermal hysteresis
Table 11 “Reset Behavior SBC”
on Page 25
OT prewarning
SPI status output
SPI status latched until
next read-out
internal supply
[SBC]
(VS related)
VINT-UV
(internal) Reset; register settings –
cleared; SPI status output; see
Table 11 “Reset Behavior SBC”
on Page 25
LS-Switches
OC, OT
LSx-shutdown; SPI status output;
signalization via ERR pin
re-activation via SPI
command; SPI status
latched until next read-out
microcontroller error
signalization (ERR)
LSx-shutdown; see “Error
re-activation via SPI
Interconnect (ERR)” on Page 32 command
Supply Output
OC, OT
Supply-shutdown; SPI status
output
re-activation via SPI
command; SPI status
latched until next read-out
Data Sheet
23
Rev. 3.01, 2008-04-15