State Machine
4.2.9 SBC Fail-Safe Mode
In SBC Fail-Safe Mode, all voltage regulators are OFF and the transceivers are in Wake-Capable Mode. The Limp
Home output is active.
Conditions to enter the SBC Fail-Safe Mode are:
• Watchdog trigger failure in configuration 2 or 4
• Vcc1µC undervoltage time-out in any configuration if VS is above VLHUV range.
• Temperature shutdown of Vcc1µC in any configuration.
• Reset clamped in Config. 2/4
In case of Vcc1µC overtemperature shutdown, the SBC will latch and wait to cool down below the thermal hysteresis,
and will go back to SBC Restart Mode.
In case of a wake-up event, the SBC will go to SBC Restart Mode (not in case of Vcc1µC overtemperature
shutdown), storing the wake-up event and resetting the Watchdog trigger failure counter. The first SPI output data
when going to SBC Normal Mode will always indicate the reason for the SBC Fail-Safe Mode.
4.2.10 SBC Software Development Mode
If the Test pin is connected to GND (Config 0 active) during powering-up, the SBC enters SBC Software
Development Mode. SBC Software Development Mode is a super set of the other modes so it is possible to use
all the modes of the SBC with the following difference. In SBC Software Development Mode, no reset is generated
and VCC1µC is not switched off due to Watchdog trigger failure. If a Watchdog trigger failure occurs, it will be
indicated by the INT output (reset bit). The SBC Fail-Safe Mode or SBC Restart Mode are not reached in case of
wrong Watchdog trigger but the other reasons to enter these modes are still valid.
4.2.11 SBC Factory Flash Mode
In this mode, the SBC is completely powered OFF and the microcontroller is supplied externally. The mode is
detected when VCC1µC is powered from external and the voltage on Vs is not powered from external. The current
flow out of Vs must be limited to the maximum rating. The external supply voltage should be below the absolute
maximum rating stated in Chapter 5.1. The reset can be driven by an external circuit, or pulled high with a pull-up
resistor.
Note: Please respect the absolute maximum ratings when the device is in SBC Factory Flash Mode.