English
Language : 

TLE4966V-1K_15 Datasheet, PDF (12/24 Pages) Infineon Technologies AG – In Plane Sensing with Vertical Dual Hall Effect Latch for Automotive Applications
TLE4966V-1K
Functional Description
2.4
Start-up Behavior
The magnetic threshold exhibit a hysteresis Bhys = Bop - Brp. In case of a power-on with a magnetic field B within
hysteresis (Brp < B < Bop) the output of the sensor is set to the pull up voltage level “Vq” per default. After the first
crossing of Bop or Brp of the magnetic field the internal decision logic is set to the corresponding magnetic input
value.
VDDA is the internal supply voltage which is following the external supply voltage VDD.
This means for B > Bop the output is switching for B > Brp and Bop > B > Brp the output stays at VQ
VDDA
tPon
3.5V
Power on ramp
VQ
Magnetic field above threshold
B > BOP
VQ
Magnetic field below threshold
B < BRP
VQ
Magnetic field in hysteresis
BOP > B > BRP
The device always applies
VQ level at start -up
t
independent from the
applied magnetic field !
t
t
t
Figure 2-5 Start-up behavior of the at different magnetic start conditions
Data Sheet
12
Revision 1.0, 2014-05-13