English
Language : 

83905 Datasheet, PDF (6/21 Pages) Integrated Device Technology – Low Skew, 1:6 Crystal-to-LVCMOS/ LVTTL Fanout Buffer
83905 Datasheet
AC Electrical Characteristics
Table 6A. AC Characteristics, VDD = VDDO = 3.3V ± 5%, TA = 0°C to 70°C
Symbol Parameter
Test Conditions
fMAX
Using External Crystal
Output Frequency Using External Clock
Source NOTE 1
tsk(o) Output Skew; NOTE 2, 3
tjit(Ø) RMS Phase Jitter (Random); NOTE 4
25MHz, Integration Range:
100Hz – 1MHz
tR / tF
odc
Output Rise/Fall Time
Output Duty Cycle
20% to 80%
tEN
Output Enable
Time; NOTE 5
ENABLE1
ENABLE2
tDIS
Output Disable
Time; NOTE 5
ENABLE1
ENABLE2
Minimum
10
DC
200
48
Typical
0.13
Maximum Units
40
MHz
100
MHz
80
ps
ps
800
ps
52
%
4
cycles
4
cycles
4
cycles
4
cycles
NOTE: Electrical parameters are guaranteed over the specified ambient operating temperature range, which is established when the
device is mounted in a test socket with maintained transverse airflow greater than 500 lfpm. The device will meet specifications after
thermal equilibrium has been reached under these conditions.
All parameters measured at ƒ  fMAX using a crystal input unless noted otherwise.
Terminated at 50 to VDDO/2.
NOTE 1: XTAL_IN can be overdriven by a single-ended LVCMOS signal. Please refer to Application Information section.
NOTE 2: Defined as skew between outputs at the same supply voltage and with equal load conditions. Measured at VDDO/2.
NOTE 3: This parameter is defined in accordance with JEDEC Standard 65.
NOTE 4: See phase noise plot.
NOTE 5: These parameters are guaranteed by characterization. Not tested in production.
Table 6B. AC Characteristics, VDD = VDDO = 2.5V ± 5%, TA = 0°C to 70°C
Symbol Parameter
Test Conditions
fMAX
Using External Crystal
Output Frequency Using External Clock
Source NOTE 1
tsk(o) Output Skew; NOTE 2, 3
tjit
RMS Phase Jitter (Random); NOTE 4
25MHz, Integration Range:
100Hz – 1MHz
tR / tF
odc
Output Rise/Fall Time
Output Duty Cycle
20% to 80%
tEN
Output Enable
Time; NOTE 5
ENABLE1
ENABLE2
tDIS
Output Disable
Time; NOTE 5
ENABLE1
ENABLE2
Minimum
10
DC
200
47
Typical
0.26
Maximum Units
40
MHz
100
MHz
80
ps
ps
800
ps
53
%
4
cycles
4
cycles
4
cycles
4
cycles
NOTE: Electrical parameters are guaranteed over the specified ambient operating temperature range, which is established when the
device is mounted in a test socket with maintained transverse airflow greater than 500 lfpm. The device will meet specifications after
thermal equilibrium has been reached under these conditions.
All parameters measured at ƒ  fMAX using a crystal input unless noted otherwise.
Terminated at 50 to VDDO/2.
NOTE 1: XTAL_IN can be overdriven by a single-ended LVCMOS signal. Please refer to Application Information section.
NOTE 2: Defined as skew between outputs at the same supply voltage and with equal load conditions. Measured at VDDO/2.
NOTE 3: This parameter is defined in accordance with JEDEC Standard 65.
NOTE 4: See phase noise plot.
NOTE 5: These parameters are guaranteed by characterization. Not tested in production.
©2016 Integrated Device Technology, Inc.
6
Revision D September 27, 2016