English
Language : 

IC-PV Datasheet, PDF (9/28 Pages) IC-Haus GmbH – BATTERY-BUFFERED HALL MULTITURN ENCODER
iC-PV
BATTERY-BUFFERED HALL MULTITURN ENCODER
Rev E2, Page 9/28
OPERATING REQUIREMENTS: Serial and Parallel Interface
Operating conditions: VDD = 3.0...5.5 V, VBAT < VDD + 1 V, Tj = -40...125 °C, fslow calibrated to 8.5 kHz with IBIAS,
3 mm Ø NdFeB magnet, unless otherwise stated.
Item Symbol Parameter
No.
Conditions
Min.
Unit
Max.
Serial Interface to Singleturn Sensor in SSI-Mode (INT_MODE = 0)
I001 tpowr
Delay Power up to SSI Request
I002 treq
Request Signal lo Level Duration
I003 tperiod
Permissible Clock Period
I005 thi
Clock Signal hi Level Duration
I006 tlo
Clock Signal lo Level Duration
I007 tcycle
Cyclic Multiturn Data Request Interval
Serial Interface to Singleturn Sensor in CHAIN-Mode (INT_MODE = 1)
20
µs
50
ns
0.25
2·tout
µs
50
ns
50
ns
85
µs
I008 tpowup
Delay Power up to SSI Request
I009 tperiod
Permissible Clock Period
I011 tic
Data IN Setup Time
I012 tci
Data IN Hold Time
Parallel Output Mode
20
µs
0.25
2·tout
µs
30
ns
30
ns
I013 tstart
Length of Start Pulse on PRE Pin
see Figure 10
1
µs
I014 tcycle
Time between two Consecutive Sensor see Figure 10
Read Cycles
30
µs
CLK
DO
t
t
req
period
REQ
MT MSB MSB-1 MSB-2
MT LSB Sync 2 Sync 1 Sync 0 ERROR PARITY
tt
t
t
out
hi lo
phase
t
cycle
Figure 1: I/O line signals of the serial interface in SSI mode (INT_MODE = 0).
NSEL
to iC-LNB/LNG only
DI
CLK
tt
ic ci
ST MSB
MSB-1
t
period
ST LSB DIN
DIN
DO
MT MSB
t
phase
MSB-1
MSB-2
Sample ST MSB
for synchronisation
(first CLK rising edge)
MT LSB ST MSB
ST LSB DIN
DIN
t
cycle
t
out
Figure 2: I/O line signals of the serial interface in chain mode (INT_MODE = 1). Usage with iC-LNG/LNB
optical singleturn encoder only.