English
Language : 

IC-PV Datasheet, PDF (24/28 Pages) IC-Haus GmbH – BATTERY-BUFFERED HALL MULTITURN ENCODER
iC-PV
BATTERY-BUFFERED HALL MULTITURN ENCODER
Rev E2, Page 24/28
APPLICATION NOTES: iC-PV as battery powered revolution counter or metering device
Figure 17: Application example principle. iC-PV as battery powered multiturn counter, e.g. in a metering
application. Interface operating in SSI-Mode (INT_MODE = 0) is used to readout the internal
counter value. iC-PV is battery powered. VDD Supply is only needed during readout. EEPROM
programming inline over SCL/SDA.
Note: All circuit examples shown in this chapter are principle wiring diagrams. Further components may be
necessary but are omitted for clarification of the application principle.