English
Language : 

IC-MH8_14 Datasheet, PDF (8/25 Pages) IC-Haus GmbH – 12 BIT ANGULAR HALL ENCODER
iC-MH8
12 BIT ANGULAR HALL ENCODER
preliminary
Rev A1, Page 8/25
OPERATING REQUIREMENTS: Serial Interface
Operating conditions: VPA, VPD = 5 V ±10 %, Ta = -40...125 ◦C, IBM calibrated to 200 µA;
Logic levels referenced to VND: lo = 0...0.45 V, hi = 2.4 V...VPD
Item Symbol Parameter
No.
Conditions
SSI Protocol (ENSSI = 1)
I001
I002
I003
TMAS
tMASh
tMASl
Permissible Clock Period
Clock Signal Hi Level Duration
Clock Signal Lo Level Duration
tout determined by CFGTOS
Min.
Unit
Max.
250
2x tout
ns
25
tout
ns
25
tout
ns
Figure 1: I/O Interface timing with SSI protocol