English
Language : 

IC-MH8_14 Datasheet, PDF (24/25 Pages) IC-Haus GmbH – 12 BIT ANGULAR HALL ENCODER
iC-MH8
12 BIT ANGULAR HALL ENCODER
preliminary
able. The addresses 0x10 to 0x1F and 0x77 are read-
only. With CFGPROT = ’1’, all registers except the ad-
dresses 0x7B and 0x7C are write-protected; the ad-
dresses 0x77 to 0x7F are readable, while all others
are read-protected.
An internal programming algorithm for the ZAP diodes
is started by setting the bit PROGZAP. This process
can only be successful if the voltage at VZAP is greater
than 6.5 V and the test register TEST (2:0) is not set.
Following programming, the register is reset internally
again. In the process, the bit PROGOK is set in the
status register (address 0x77) when programming is
successful, and the bit PROGERR if it is not.
The ZAP memory can be tested by reading the regis-
ter range 0x10-0x1f. This test can be done with with a
higher readout current (Bit ENHC=1) to simulate dete-
riorated working conditions.
Rev A1, Page 24/25
100 nF
100 nF
VPD VPA
VZAP
MA
iC-MH8
SLI
SLO
VND VNA1 VNA2
100 nF 10 µF
Programming
Board
+ 5V
+ 7V
Serial
Interface
0V
Figure 26: Recommended setup for external program-
ming. A short low impedance path (shown in
light red) must be provided directly from pin
VZAP to pins VNA1, VNA2.
For reliable ROM writing, a low impedance connection
path as shown in Figure 26 must be established for the
VZAP blocking capacitor (about 100 nF) between pin
VZAP and pins VNA1, VNA2 to ensure stable VZAP
voltage during programming. A further capacitor of
10 µF which may be located externally (e.g. on the pro-
gramming board) is recommended for additional block-
ing purpose.
A typical PCB layout may look like the one shown in
Figure 27.
Figure 27: Example PCB layout showing low impedance
connection of capacitors to supply voltages
(VPA, VPD, VZAP) and common ground
iC-Haus expressly reserves the right to change its products and/or specifications. An info letter gives details as to any amendments and additions made to the
relevant current specifications on our internet website www.ichaus.de/infoletter; this letter is generated automatically and shall be sent to registered users by
email.
Copying – even as an excerpt – is only permitted with iC-Haus’ approval in writing and precise reference to source.
iC-Haus does not warrant the accuracy, completeness or timeliness of the specification and does not assume liability for any errors or omissions in these
materials.
The data specified is intended solely for the purpose of product description. No representations or warranties, either express or implied, of merchantability, fitness
for a particular purpose or of any other nature are made hereunder with respect to information/specification or the products to which information refers and no
guarantee with respect to compliance to the intended use is given. In particular, this also applies to the stated possible applications or areas of applications of
the product.
iC-Haus conveys no patent, copyright, mask work right or other trade mark right to this product. iC-Haus assumes no liability for any patent and/or other trade
mark rights of a third party resulting from processing or handling of the product and/or any other use of the product.