English
Language : 

IC-MSB_17 Datasheet, PDF (18/32 Pages) IC-Haus GmbH – SIN/COS SIGNAL CONDITIONER
iC-MSBSAFETY, iC-MSB2
SIN/COS SIGNAL CONDITIONER WITH 1Vpp DRIVER
OPERATING MODES
Rev F3, Page 18/32
In order to calibrate iC-MSB, compensate for the input
signals and test iC-MSB the mode of operation must be
changed. The output function changes according to the
various operating modes; the line drivers and protection
against reverse polarity facility are only active in normal
mode.
MODE(3:0)
Addr. 0x02; bit 3:0
BYP
Addr. 0x0D; bit 5
Code
Operating Mode
Pin PS
Pin NS
Pin PC
Pin NC
Pin PZ
Pin NZ
Pin ERR
0x00
Normal operation
PS
NS
PC
NC
PZ
NZ
ERR
0x01
Calibration 1
TANA0(2) VREFI0
VREFI12 IBN
PZI
NZI
ERR
0x02
Calibration 2, BYP = 0
PCH1
NCH1
PCH2
NCH2
VDC1
VDC2
—
Calibration 2, BYP = 1* X4
X6
X3
X5
X1
X2
0x03
iC-Haus Test 1
VPAH
VPD
—
CGUCK IPF
V05
IERR
0x04
iC-Haus Test 2
PS_out
NS_out
PC_out
NC_out
PZ_out
NZ_out
IERR
0x05
iC-Haus Test 3
PS_out
NS_out
PC_out
NC_out
PZ_out
NZ_out
ERR
0x06
iC-Haus Test 4, BYP = 0 TANA12(0) TANA12(1) TANA12(2) TANA12(3) TANA12(4) TANA12(5) IERR
iC-Haus Test 4, BYP = 1* X4
X6
X3
X5
X1
X2
0x07
Calibration 3
VTs
VTth
—
—
—
—
ERR
0x08
Saturation low
SCL, SDA and ERR low
0x09
—
—
—
—
—
—
—
—
0x0A
iC-Haus Test 5
TP
CLK6
—
—
—
—
—
0x0B
—
—
—
—
—
—
—
—
0x0C
—
—
—
—
—
—
—
—
0x0D
—
—
—
—
—
—
—
—
0x0E
IDDQ-Test
All PU/PD resistors, oscillator and supply voltage deactivated
0x0F
—
—
—
—
—
—
—
—
Notes
Analog calibration signals are output via approx. 5 kΩ source impedance (see Elec. Char. No.507).
For accuracy of calibration the signal frequency should not exceed 2 kHz (see Elec. Char. No.508).
* Bypass function: inputs (without voltage divider) to outputs, approx. 7 kΩ source impedance (see Elec. Char. No.509).
Table 13: Selection of Operating Modes
Calibration Op. Modes
In Calibration Mode 1 the user can measure the BIAS
current (IBN), input amplifier reference potential VREFI
and the analog signals from channel 0 following signal
conditioning (PCH0 and NCH0).
In Calibration Mode 2 the conditioned signals from
channels 1 and 2 are output (PCH1, NCH1, PCH2
and NCH2). In addition the intermediate potentials of
the compensating circuits are also available for CH1
(VDC1) and CH2 (VDC2).
In Calibration Mode 3 the internal temperature monitor-
ing signals are provided.
Signal Filter
iC-MSB has a noise limiting signal filter to filter the con-
ditioned analog signals. This can be activated using
ENF.
ENF
Code
0
1
Adr 0x0E, bit 7
Function
Noise limiter deactivated
Noise limiter activated
Table 14: Signal Filtering
Special Device Test Functions
IDDQ-Test, Saturation Low, Saturation High, and Test
1 to 5 are test modes for iC-Haus device tests. With
an activated bypass (BYP = 1), mode iC-Haus Test 4
permits the direct feedthrough of X1 - X6 input signals
to the output pins; in this instance the output impedance
is high-ohmic. Furthermore, if the input voltage divider
is selected (by RINx = 1- -1), it reduces the signal ampli-
tudes to approx. 7/8.