IC-MSB_17 Datasheet, PDF (17/32 Pages) IC-Haus GmbH – SIN/COS SIGNAL CONDITIONER
iC-MSBSAFETY, iC-MSB2
SIN/COS SIGNAL CONDITIONER WITH 1Vpp DRIVER
BIAS SOURCE AND TEMPERATURE SENSOR CALIBRATION
Rev F3, Page 17/32
Bias Source Calibration
The calibration of the bias current source in operation
mode Calibration 1 (Tab. 13) is prerequisite for ad-
herence to the given electrical characteristics and also
instrumental in the determination of the chip timing (e.g.
SCL clock frequency). For setup purposes the IBN
value is measured using a 10 kΩ resistor by pin VDDS
connected to pin NC. The setpoint is 200 µA which is
equivalent to a measurement voltage of 2 V.
Example: VTs(T1) is approx. 650 mV, measured from
VDDS versus PS, with T1 = 25 °C;
The necessary activation threshold voltage VTth(T1) is
then calculated. The required warning temperature T2,
temperature coefficients TCs and TCth (see Electrical
Characteristics, Section E) and measurement value
VTs(T1) are entered into this calculation:
Note: The measurement delivers a false reading
when outputs are tristate (due to a configuration error
after cycling power, for instance).
CFGIBN
Code k
0x0
0x1
0x2
0x3
0x4
0x5
0x6
0x7
Adr 0x01, bit 7:4
IBN
∼
31
39−k
79 %
81 %
84 %
86 %
88 %
91 %
94 %
97 %
Code k
0x8
0x9
0xA
0xB
0xC
0xD
0xE
0xF
IBN
∼
31
39−k
100 %
103 %
107 %
111 %
115 %
119 %
124 %
129 %
Table 11: Bias Current Source Calibration
Temperature Sensor
The temperature monitor is calibrated in operating
mode Calibration Mode 3.
To set the required warning temperature T2 the tem-
perature sensor voltage VTs at which the warning is
generated is first determined. To this end a voltage
ramp from VDDS towards GNDS is applied to pin PS
until pin ERR triggers an error message (for EMASKA =
0x20 and EMTD = 0x00).
VTth(T1)
=
VTs(T1) + TCs · (T2 − T1)
1 + TCth · (T2 − T1)
Example: For T2 = T1 + 100 K, VTth(T1) must be pro-
grammed to 443 mV.
Activation threshold voltage VTth(T1) is provided for a
high impedance measurement (10 MΩ) at output pin
NS (measurement versus VDDS) and must be set by
programming CFGTA(3:0) to the calculated value.
Example: Altering VTth(T1) from 310 mV (measured
with CFGTA(3:0)= 0x0) to 443 mV is equivalent to
143 %, the closest value for CFGTA is 0x9;
CFGTA
Code k
0x0
0x1
0x2
0x3
0x4
0x5
0x6
0x7
Notes
Adr 0x01, bit 3:0
VTth
∼
65+3k
65
100 %
Code k
0x8
VTth
∼
65+3k
65
140 %
105 %
0x9
145 %
110 %
0xA
150 %
115 %
0xB
155 %
120 %
0xC
160 %
125 %
0xD
165 %
130 %
0xE
170 %
135 %
0xF
175 %
With CFGTA = 0xF Toff is 80 °C typ.,
with CFGTA = 0x0 Toff is 155 °C typ.
Table 12: Calibration of Temperature Monitoring