English
Language : 

IC-MSA Datasheet, PDF (16/29 Pages) IC-Haus GmbH – SIN/COS SIGNAL CONDITIONER with AGC and 1Vpp DRIVER
iC-MSA SIN/COS SIGNAL
preliminary
CONDITIONER with AGC and 1Vpp DRIVER
OPERATING MODES
Rev A1, Page 16/29
In order to calibrate iC-MSA, compensate for the input
signals and test iC-MSA the mode of operation must
be changed. The output function changes according
to the various operating modes; the line drivers and
protection against reverse polarity facility are only ac-
tive in normal mode.
MODE(3:0)
BYP
Code
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
Operating Mode
Normal operation
Calibration 1
Calibration 2
iC-Haus Test 1
iC-Haus Test 2
iC-Haus Test 3
iC-Haus Test 4, BYP = 0
iC-Haus Test 4, BYP = 1
Calibration 3
Saturation low
—
iC-Haus Test 5
—
—
—
IDDQ-Test
—
Addr. 0x42; bit 3:0
Addr. 0x4D; bit 5
Pin PS
Pin NS
Pin PC
Pin NC
Pin PZ
Pin NZ
PS
NS
PC
NC
PZ
NZ
TANA0(2) VREFI0
VREFI12 IBN
PZI
NZI
PCH1
NCH1
PCH2
NCH2
—
—
VPAH
VPD
—
CGUCK IPF
V05
PS_out
NS_out
PC_out
NC_out
PZ_out
NZ_out
PS_out
NS_out
PC_out
NC_out
PZ_out
NZ_out
TANA12(0) TANA12(1) TANA12(2) TANA12(3) TANA12(4) TANA12(5)
X4
X6
X3
X5
X1
X2
VTs
VTth
—
—
—
—
SCL, SDA and ERR low
—
—
—
—
—
—
—
—
TP
CLK6
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
All PU/PD resistors, oscillator and supply voltage deactivated
—
—
—
—
—
—
Pin ERR
ERR
ERR
—
IERR
IERR
ERR
IERR
ERR
—
—
—
—
—
—
Table 13: Selection of Operating Modes
Calibration Op. Modes
In Calibration Mode 1 the user can measure the BIAS
current (IBN), input amplifier reference potential VREFI
and the analog signals from channel 0 following signal
conditioning (PCH0 and NCH0).
In Calibration Mode 2 the conditioned signals from
channels 1 and 2 are output (PCH1, NCH1, PCH2 and
NCH2).
In Calibration Mode 3 the internal temperature moni-
toring signals are provided.
Special Device Test Functions
IDDQ-Test, Saturation Low, Saturation High, and Test
1 to 5 are test modes for iC-Haus device tests. With an
activated bypass (BYP = 1), mode iC-Haus Test 4 per-
mits the direct feedthrough of X1 - X6 input signals to
the output pins; in this instance the output impedance
is high-ohmic. Furthermore, if the input voltage divider
is selected (by RINx = 1- -1), it reduces the signal am-
plitudes to approx. 7/8.
Signal Filter
iC-MSA has a noise limiting signal filter to filter the con-
ditioned analog signals. This can be activated using
ENF.
ENF
Code
0
1
Adr 0x4E, bit 7
Function
Noise limiter deactivated
Noise limiter activated
Table 14: Signal Filtering