English
Language : 

HCPL-810J Datasheet, PDF (9/16 Pages) Agilent(Hewlett-Packard) – PLC Powerline DAA IC
Electrical Specifications (Cont.)
Unless otherwise noted, for sinusoidal waveform input and reference resistor Rref = 24 kΩ, all typical values are at TA = 25°C,
VCC1 = 5 V, VCC2 = 5 V; all Minimum/Maximum specifications are at Recommended Operating Conditions.
Receiver
Parameter
Input Impedance
Output Impedance
(Rx-PD-out)
Input Referred Noise
Bandwidth (Rx-PD-out)
Gain
Symbol
ZI, Rx
ZO, RxPD
Min.
Vnr
BWRxPD
GR1
Set-up Time (Rx-PD-out) ts, Rx
Receiver Output Amplifier (RxAMP)
DC Biased Voltage
Output Impedance
Gain Bandwidth Product
VBias, Rx
ZO, RxA
GBWRxA
Typ. Max. Unit Test Condition
Fig. Note
4
kΩ VTx-en = 0 V, f = 132 kHz
30
Ω
VTx-en = 0 V, f = 132 kHz
70
nV/ Hz VTx-en = 0 V, VRx-in = 0 VPP
500
kHz VTx-en = 0 V
20
dB
VTx-en = 0 V, VRx-in = 0.05 11
VPP, f = 132 kHz
10
µs
VTx-en = 0 V, f = 132 kHz
2.27
V
20
Ω
VTx-en = 0 V, f = 132 kHz
28
MHz VTx-en = 0 V, f = 132 kHz, 12
VRx-in = 0.1 VPP, GR2 = −20,
feedback resistor 20 kΩ
9