English
Language : 

HCPL-810J Datasheet, PDF (5/16 Pages) Agilent(Hewlett-Packard) – PLC Powerline DAA IC
Regulatory Information
The HCPL-810J is pending for approval by the following organizations:
IEC/EN/DIN EN 60747- 5- 2
UL
Approved under:
Recognized under UL 1577,
IEC 60747-5-2:1997 + A1:2002
component recognition program,
EN 60747-5-2:2001 + A1:2002
File E55361.
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01
with VIORM = 891 Vpeak.
CSA
Approved under CSA
Acceptance Notice #5,
File CA 88324.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics (1)
Description
Symbol
Characteristic Unit
Installation classification per DIN VDE 0110/1.89, Table 1
For rated mains voltage ≤ 150 Vrms
For rated mains voltage ≤ 300 Vrms
For rated mains voltage ≤ 600 Vrms
Climatic Classification
I – IV
I – III
I – II
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b (2)
VIORM
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
VPR
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a (2)
VIORM x 1.5 = VPR, Type and Sample Test, tm = 60 sec,
VPR
Partial Discharge < 5 pC
Highest Allowable Over-voltage (2)
(Transient Over-voltage tini = 10 sec)
VIOTM
Safety-limiting values − maximum values allowed in the event of a failure
Case Temperature
Control Side Power (3)
Line Side Power (3)
TS
PS, INPUT
PS, OUTPUT
Insulation Resistance at TS, VIO = 500 V
RS
Notes:
1. Isolation characteristics are guaranteed only within the safety maximum ratings that
1600
must be ensured by protective circuits in application. Surface mount classification is class
1400
A in accordance with CECCOO802.
2. Refer to the optocoupler section of the Isolation and Control Component Designer’s
1200
Catalog, under Product Safety Regulations section, (IEC/EN/DIN EN 60747-5-2) for a
1000
detailed description of Method a and Method b partial discharge test profiles.
3. Refer to the following figure for dependence of PS, INPUT and PS, OUTPUT on case
800
temperature.
600
891
1670
1336
6000
175
400
1500
>109
VPEAK
VPEAK
VPEAK
VPEAK
°C
mW
mW
Ω
PS, OUTPUT
PS, INPUT
400
200
0
0 25 50 75 100 125 150 175 200
TS – CASE TEMPERATURE – °C
5