English
Language : 

HDMP-1637A Datasheet, PDF (4/16 Pages) Agilent(Hewlett-Packard) – Gigabit Ethernet SerDes Circuit with Differential PECL Clock Inputs
4
FRAME DEMUX AND BYTE
SYNC
The FRAME DEMUX AND BYTE
SYNC block is responsible for
restoring the 10-bit parallel data
from the high speed serial bit
stream. This block is also
responsible for recognizing the
comma character (or a K28.5
character) of positive disparity
(0011111xxx). When
recognized, the FRAME DEMUX
AND BYTE SYNC block works
with the RX PLL/CLOCK
RECOVERY block to properly
align the receive byte clocks to
the parallel data. When a comma
character is detected and
realignment of the receiver byte
clocks (RBC1/RBC0) is
necessary, these clocks are
stretched, not slivered, to the
next possible correct alignment
position. These clocks will be
fully aligned by the start of the
second 2-byte ordered set. The
second comma character
received shall be aligned with the
rising edge of RBC1. As per the
8B/10B encoding scheme,
comma characters must not be
transmitted in consecutive bytes
to allow the receiver byte clocks
to maintain their proper
recovered frequencies.
OUTPUT DRIVERS
The OUTPUT DRIVERS present
the 10-bit parallel recovered data
byte properly aligned to the
receive byte clocks (RBC1/
RBC0), as shown in Figure 5.
These output data buffers
provide TTL compatible signals.
SIGNAL DETECT
The SIGNAL DETECT block
examines the differential
amplitude of the inputs ± DIN.
When this input signal is too
small, it outputs a logic 0 at
SIG_DET (refer to SIG_DET pin
definition for detection
thresholds), and at the same
time, forces the parallel output
RX[0]..RX[9] to all logic one
(1111111111). The main
purpose of this circuit is to
prevent the generation of random
data when the serial input lines
are disconnected. When the
signal at ± DIN is of a valid
amplitude, SIG_DET is set to
logic 1, and the output of the
INPUT SELECT block is passed
through.