Table 19. RX Modem Configuration for OOK with Manchester Disabled
Appl Parameters
Rb
Fd
[kbps]
[kHz]
1.2
75
1.2
110
1.2
335
1.2
420
1.2
620
2.4
335
4.8
335
9.6
335
10
335
15
335
19.2
335
20
335
30
335
38.4
335
40
335
RX Modem Setting Examples for OOK (Manchester Disabled)
Register Values
dwn3_bypass ndec_exp[2:0] filset[3:0] rxosr[10:0] ncoff[19:0]
1Ch
1Ch
1Ch
20,21h
21,22,23h
0
4
1
0D0
09D49
0
4
5
0D0
09D49
1
4
8
271
0346E
1
4
A
271
0346E
1
4
E
271
0346E
1
3
8
271
0346E
1
2
8
271
0346E
1
1
8
271
0346E
1
1
8
258
0369D
1
1
8
190
051EC
1
1
8
139
068DC
1
1
8
12C
06D3A
1
1
8
0C8
0A3D7
1
1
8
09C
0D1B7
1
1
8
096
0DA74
crgain[10:0]
24,25h
13D
13D
06B
06B
06B
06B
06B
06B
06F
0A6
0D3
0DC
14A
1A6
1B7
Table 20. RX Modem Configuration for OOK with Manchester Enabled
Appl Parameters
Rb
Fd
[kbps]
[kHz]
1.2
75
1.2
110
1.2
335
1.2
420
1.2
620
2.4
335
4.8
335
9.6
335
10
335
15
335
19.2
335
20
335
30
335
38.4
335
40
335
RX Modem Setting Examples for OOK (Manchester Disabled)
Register Values
dwn3_bypass ndec_exp[2:0] filset[3:0] rxosr[10:0] ncoff[19:0]
1Ch
1Ch
1Ch
20,21h
21,22,23h
0
3
1
0D0
04EA5
0
3
5
0D0
04EA5
1
3
8
271
01A37
1
3
A
271
01A37
1
3
E
271
01A37
1
2
8
271
01A37
1
1
8
271
01A37
1
1
8
139
0346E
1
1
8
12C
0369D
1
1
8
0C8
051EC
1
1
8
09C
068DC
1
1
8
096
06D3A
1
0
8
0C8
051EC
1
0
8
09C
068DC
1
0
8
096
06D3A
crgain[10:0]
24,25h
13D
13D
06B
06B
06B
06B
06B
0D3
0DC
14A
1A6
1B7
14A
1A6
1B7
40