Chapter 12 Freescaleâs Controller Area Network (S08MSCANV1)
12.6.2 Bus-Off Recovery
The bus-off recovery is user conï¬gurable. The bus-off state can either be exited automatically or on user
request.
For reasons of backwards compatibility, the MSCAN defaults to automatic recovery after reset. In this
case, the MSCAN will become error active again after counting 128 occurrences of 11 consecutive
recessive bits on the CAN bus (See the Bosch CAN speciï¬cation for details).
If the MSCAN is conï¬gured for user request (BORM set in Section 12.3.2, âMSCAN Control Register 1
(CANCTL1)â), the recovery from bus-off starts after both independent events have become true:
⢠128 occurrences of 11 consecutive recessive bits on the CAN bus have been monitored
⢠BOHOLD in Section 12.3.12, âMSCAN Miscellaneous Register (CANMISC) has been cleared by
the user
These two events may occur in any order.