English
Language : 

MC68HC908QY4CDW Datasheet, PDF (129/184 Pages) Freescale Semiconductor, Inc – Microcontrollers
Input/Output Registers
14.9.3 TIM Counter Modulo Registers
The read/write TIM modulo registers contain the modulo value for the TIM counter. When the TIM counter
reaches the modulo value, the overflow flag (TOF) becomes set, and the TIM counter resumes counting
from $0000 at the next timer clock. Writing to the high byte (TMODH) inhibits the TOF bit and overflow
interrupts until the low byte (TMODL) is written. Reset sets the TIM counter modulo registers.
Address: $0023 TMODH
Bit 7
6
5
4
3
2
1
Bit 0
Read:
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Write:
Reset: 1
1
1
1
1
1
1
1
Address: $0024 TMODL
Bit 7
6
5
4
3
2
1
Bit 0
Read:
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Write:
Reset: 1
1
1
1
1
1
1
1
Figure 14-6. TIM Counter Modulo Registers (TMODH:TMODL)
NOTE
Reset the TIM counter before writing to the TIM counter modulo registers.
14.9.4 TIM Channel Status and Control Registers
Each of the TIM channel status and control registers does the following:
• Flags input captures and output compares
• Enables input capture and output compare interrupts
• Selects input capture, output compare, or PWM operation
• Selects high, low, or toggling output on output compare
• Selects rising edge, falling edge, or any edge as the active input capture trigger
• Selects output toggling on TIM overflow
• Selects 0% and 100% PWM duty cycle
• Selects buffered or unbuffered output compare/PWM operation
MC68HC908QY/QT Family Data Sheet, Rev. 6
Freescale Semiconductor
129