English
Language : 

XR16M564 Datasheet, PDF (7/55 Pages) Exar Corporation – 1.62V TO 3.63V QUAD UART WITH 32-BYTE FIFO
REV. 1.0.0
Pin Description
XR16M564/564D
1.62V TO 3.63V QUAD UART WITH 32-BYTE FIFO
NAME
48-QFN
PIN #
64-LQFP 68-PLCC 80-LQFP
PIN #
PIN #
PIN #
TYPE
DESCRIPTION
CDA#
-
CDB#
-
CDC#
-
CDD#
-
64
9
19
I UART channels A-D Carrier-Detect (active low) or
18
27
42
31
43
59
49
61
2
general purpose input. This input should be connected
to VCC when not used. This input has no effect on the
UART.
RIA#
-
63
8
18
I UART channels A-D Ring-Indicator (active low) or gen-
RIB#
-
19
28
43
RIC#
-
30
42
58
RID#
-
50
62
3
eral purpose input. This input should be connected to
VCC when not used. This input has no effect on the
UART.
ANCILLARY SIGNALS
XTAL1
18
25
35
50
I Crystal or external clock input.
XTAL2
19
26
36
51
O Crystal or buffered clock output.
16/68#
14
-
31
-
I Intel or Motorola Bus Select (input with internal pull-
up).
When 16/68# pin is HIGH, 16 or Intel Mode, the device
will operate in the Intel bus type of interface.
When 16/68# pin is LOW, 68 or Motorola mode, the
device will operate in the Motorola bus type of inter-
face.
Motorola bus interface is not available on the 64 pin
package.
CLKSEL
-
21
30
-
I Baud-Rate-Generator Input Clock Prescaler Select for
channels A-D. This input is only sampled during power
up or a reset. Connect to VCC for divide by 1 (default)
and GND for divide by 4. MCR[7] can override the
state of this pin following a reset or initialization. See
MCR bit-7 and Figure 6 in the Baud Rate Generator
section.
RESET
20
27
37
53
I When 16/68# pin is HIGH for Intel bus interface, this
(RESET#)
input becomes the Reset pin (active high). In this
case, a 40 ns minimum HIGH pulse on this pin will
reset the internal registers and all outputs. The UART
transmitter output will be held HIGH, the receiver input
will be ignored and outputs are reset during reset
period (Table 17). When 16/68# pin is at LOW for
Motorola bus interface, this input becomes Reset# pin
(active low). This pin functions similarly, but instead of
a HIGH pulse, a 40 ns minimum LOW pulse will reset
the internal registers and outputs.
Motorola bus interface is not available on the 64 pin
package.
VCC
2, 24, 37 4, 35, 52 13, 47, 5, 25, 45, Pwr 1.62V to 3.63V power supply.
64
65
GND
21, 47
14, 28, 6, 23, 40, 16, 36, Pwr Power supply common, ground.
45, 61
57
56, 76
7