HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
AFR[0]: Concurrent Write Mode
When this bit is set, the CPU can write concurrently to the same register in both UARTs. This function is
intended to reduce the dual UART initialization time. It can be used by the CPU when both channels are
initialized to the same state. The external CPU can set or clear this bit by accessing either register set. When
this bit is set, the channel select pin still selects the channel to be accessed during read operations. The user
should ensure that LCR Bit-7 of both channels are in the same state before executing a concurrent write to the
registers at address 0, 1, or 2.
• Logic 0 = No concurrent write (default).
• Logic 1 = Register set A and B are written concurrently with a single external CPU I/O write operation.
AFR[2:1]: MF# Output Select
These bits select a signal function for output on the MF# A/B pins. These signal function are described as:
OP2#, BAUDOUT#, or RXRDY#. Only one signal function can be selected at a time.
BIT-2
0
0
1
1
BIT-1
0
1
0
1
MF# FUNCTION
OP2# (default)
BAUDOUT#
RXRDY#
Reserved
AFR[7:3]: Reserved
All are initialized to logic 0.
4.14 Device Identification Register (DVID) - Read Only
This register contains the device ID (0x0A for XR16V2752). Prior to reading this register, DLL and DLM should
be set to 0x00 (DLD = 0xXX).
4.15 Device Revision Register (DREV) - Read Only
This register contains the device revision information. For example, 0x01 means revision A. Prior to reading
this register, DLL and DLM should be set to 0x00 (DLD = 0xXX).
4.16 Trigger Level Register (TRG) - Write-Only
User Programmable Transmit/Receive Trigger Level Register. If both the TX and RX trigger levels are used,
the TX trigger levels must be set before the RX trigger levels.
TRG[7:0]: Trigger Level Register
These bits are used to program desired trigger levels when trigger Table-D is selected. FCTR bit-7 selects
between programming the RX Trigger Level (a logic 0) and the TX Trigger Level (a logic 1).
4.17 RX/TX FIFO Level Count Register (FC) - Read-Only
This register is accessible when LCR = 0xBF. Note that this register is not identical to the FIFO Level Count
Register which is located in the general register set when FCTR bit-6 = 1 (Scratchpad Register Swap). It is
suggested to read the FIFO Level Count Register at the Scratchpad Register location when FCTR bit-6 = 1.
See Table 12.
FC[7:0]: RX/TX FIFO Level Count
Receive/Transmit FIFO Level Count. Number of characters in Receiver FIFO (FCTR[7] = 0) or Transmitter
FIFO (FCTR[7] = 1) can be read via this register. Reading this register is not recommended when transmitting
or receiving data.
4.18 Feature Control Register (FCTR) - Read/Write
This register controls the XR16V2752 new functions that are not available in ST16C2450 or ST16C2550.
35