English
Language : 

RHFAC14K01V Datasheet, PDF (8/24 Pages) List of Unclassifed Manufacturers – STANDARD MICROCIRCUIT DRAWING
TABLE I. Electrical performance characteristics - Continued.
Test and
MIL-STD-883
test method 1/
Symbol
Test conditions 2/ 3/
-55°C ≤ TC ≤ +125°C
+3.0 V ≤ VCC ≤ +5.5 V
unless otherwise specified
Functional tests
8/
3014
Propagation delay tPHL
time, An to Yn
9/
3003
For all inputs,
VIN = VIH minimum or VIL maximum
Verify output VOUT
See 4.4.1b
CL = 50 pF minimum
RL = 500Ω
See figure 4
tPLH
9/
Device
type
and
device
class
All
All
All
All
All
All
All
All
VCC Group A
subgroups
3.0 V
7, 8
5.5 V
7, 8
3.0 V
4.5 V
3.0 V
4.5 V
9
10, 11
9
10, 11
9
10, 11
9
10, 11
Limits 4/
Unit
Min Max
L
H
L
H
1.0 11.5 ns
1.0 14.0
1.0
8.5
1.0 10.0
1.0 13.5
1.0 16.0
1.0 10.0
1.0 12.0
1/ For tests not listed in the referenced MIL-STD-883, [e.g. VT+, VT-], utilize the general test procedure under the conditions
listed herein.
2/ Each input/output, as applicable, shall be tested at the specified temperature, for the specified limits, to the tests in table I
herein. Output terminals not designated shall be high level logic, low level logic, or open, except as follows:
a. For VIC+ tests, the GND terminal can be open. TC = +25°C.
b. For VIC- tests, the VCC terminal shall be open. TC = +25°C.
c. For all ICC tests, the output terminal shall be open. When performing these tests, the current meter shall be placed
in the circuit such that all current flows through the meter.
The values to be used for VIH minimum and VIL maximum shall be those values listed in section 1.4 herein.
3/ RHA parts for device type 01 meet all levels M, D, P, L, R, and F of irradiation. However, these parts are only tested at the
“F” level. Pre and post irradiation values are identical unless otherwise specified in table I. When performing post
irradiation electrical measurements for any RHA level, TA = 25°C.
4/ For negative and positive voltage and current values, the sign designates the potential difference in reference to GND and
the direction of current flow, respectively; and the absolute value of the magnitude, not the sign, is relative to the minimum
and maximum limits, as applicable, listed herein. All devices shall meet or exceed the limits specified in table I, as
applicable, at 3.0 V ≤ VCC ≤ 3.6 V and 4.5 V ≤ VCC ≤ 5.5 V.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
A
REVISION LEVEL
B
5962-87624
SHEET
8