TABLE II. Electrical test requirements.
Test requirements
Interim electrical
parameters (see 4.2)
Final electrical
parameters (see 4.2)
Group A test
requirements (see 4.4)
Group C end-point electrical
parameters (see 4.4)
Group D end-point electrical
parameters (see 4.4)
Group E end-point electrical
parameters (see 4.4)
Subgroups
(in accordance with
MIL-STD-883, method
5005, table I)
Device
class M
---
1/ 1, 2, 3, 7,
8, 9
1, 2, 3, 4, 7,
8, 9, 10, 11
1, 2, 3
1, 2, 3
1, 7, 9
Subgroups
(in accordance with
MIL-PRF-38535, table III)
Device
class Q
Device
class V
---
1
1/ 1, 2, 3, 7,
8, 9
1, 2, 3, 4, 7,
8, 9, 10, 11
1, 2, 3
2/ 3/ 1, 2, 3, 7,
8, 9, 10, 11
1, 2, 3, 4, 7,
8, 9, 10, 11
3/ 1, 2, 3, 7,
8, 9, 10, 11
1, 2, 3
1, 2, 3
1, 7, 9
1, 7, 9
1/ PDA applies to subgroup 1.
2/ PDA applies to subgroups 1, 7, and deltas.
3/ Delta limits, as specified in table III, shall be required where specified and the delta limits
shall be completed with reference to the zero hour electrical parameters.
TABLE III. Burn-in and operating life test, delta parameters (+25°C). 1/
Parameter 2/
Quiescent supply current
Input current low level
Input current high level
Output voltage low level
(VCC = 5.5 V, IOL = 24 mA)
Output voltage high level
(VCC = 5.5 V, IOH = -24 mA)
Symbol
ICCH, ICCL
IIL
IIH
VOL
VOH
Delta limits
±150 nA
±20 nA
±20 nA
±0.04 V
±0.20 V
1/ This table is representation of what vendor CAGE F8859 has
experienced and is guaranteed and not meant to be construed
as a quality assurance requirement for any other vendor.
2/ These parameters shall be recorded before and after the
required burn-in and life tests to determined delta limits.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
A
REVISION LEVEL
B
5962-87624
SHEET
15