English
Language : 

RFM66W Datasheet, PDF (78/87 Pages) List of Unclassifed Manufacturers – 868 & 915MHz Ultra Low Power High Link Budget Integrated UHF Transceiver
WIRELESS & SENSING
RFM66W
DATASHEET
Name
(Address)
Bits
RegIrqFlags1
7
(0x3e)
6
5
4
3
2
1
0
RegIrqFlags2
7
(0x3f)
6
5
4
3
2
1
0
Variable Name
ModeReady
RxReady
TxReady
PllLock
Rssi
Timeout
PreambleDetect
SyncAddressMatch
FifoFull
FifoEmpty
FifoLevel
FifoOverrun
PacketSent
PayloadReady
CrcOk
LowBat
Mode
Default
value
Description
r
- Set when the operation mode requested in Mode, is ready
- Sleep: Entering Sleep mode
- Standby: XO is running
- FS: PLL is locked
- Rx: RSSI sampling starts
- Tx: PA ramp-up completed
Cleared when changing the operating mode.
r
- Set in Rx mode, after RSSI, AGC and AFC.
Cleared when leaving Rx.
r
- Set in Tx mode, after PA ramp-up.
Cleared when leaving Tx.
r
- Set (in FS, Rx or Tx) when the PLL is locked.
Cleared when it is not.
rwp - Set in Rx when the RssiValue exceeds RssiThreshold.
Cleared when leaving Rx or setting this bit to 1.
r
- Set when a timeout occurs
Cleared when leaving Rx or FIFO is emptied.
rwp - Set when the Preamble Detector has found valid Preamble.
bit clear when set to 1
rwp - Set when Sync and Address (if enabled) are detected.
Cleared when leaving Rx or FIFO is emptied.
This bit is read only in Packet mode, rwc in Continuous mode
r
- Set when FIFO is full (i.e. contains 66 bytes), else cleared.
r
- Set when FIFO is empty, and cleared when there is at least 1
byte in the FIFO.
r
- Set when the number of bytes in the FIFO strictly exceeds
FifoThreshold, else cleared.
rwp - Set when FIFO overrun occurs. (except in Sleep mode)
Flag(s) and FIFO are cleared when this bit is set. The FIFO
then becomes immediately available for the next transmission
/ reception.
r
- Set in Tx when the complete packet has been sent.
Cleared when exiting Tx
r
- Set in Rx when the payload is ready (i.e. last byte received
and CRC, if enabled and CrcAutoClearOff is cleared, is Ok).
Cleared when FIFO is empty.
r
- Set in Rx when the CRC of the payload is Ok. Cleared when
FIFO is empty.
rwp - Set when the battery voltage drops below the Low Battery
threshold. Cleared only when set to 1 by the user.
IO control registers