English
Language : 

RF65 Datasheet, PDF (62/72 Pages) List of Unclassifed Manufacturers – Low Power Integrated UHF Receiver With -120dBm High Sensitivity
ADVANCED COMMUNICATIONS & SENSING
RF65
DATASHEET
6.5. Packet Engine Registers
Table 23 Packet Engine Registers
Name
(Address)
Reserved2C
(0x2c)
Reserved2D
(0x2d)
RegSyncConfig
(0x2e)
Bits Variable Name
7-0 -
7-0 -
7 SyncOn
6 FifoFillCondition
RegSyncValue1
(0x2f)
RegSyncValue2
(0x30)
RegSyncValue3
(0x31)
RegSyncValue4
(0x32)
RegSyncValue5
(0x33)
RegSyncValue6
(0x34)
RegSyncValue7
(0x35)
RegSyncValue8
(0x36)
5-3 SyncSize
2-0 SyncTol
7-0 SyncValue(63:56)
7-0 SyncValue(55:48)
7-0 SyncValue(47:40)
7-0 SyncValue(39:32)
7-0 SyncValue(31:24)
7-0 SyncValue(23:16)
7-0 SyncValue(15:8)
7-0 SyncValue(7:0)
Mode
Default
Value
Description
rw
0x00 unused
rw
0x03 unused
rw
1 Enables the Sync word detection:
0→ Off
1→ On
rw
0 FIFO filling condition:
0→ if SyncAddress interrupt occurs
1→ as long as FifoFillCondition is set
rw
011 Size of the Sync word:
(SyncSize + 1) bytes
rw
000 Number of tolerated bit errors in Sync word
rw
0x01 1st byte of Sync word. (MSB byte)
* Used if SyncOn is set.
rw
0x01 2nd byte of Sync word
* Used if SyncOn is set and (SyncSize +1) >= 2.
rw
0x01 3rd byte of Sync word.
* Used if SyncOn is set and (SyncSize +1) >= 3.
rw
0x01 4th byte of Sync word.
* Used if SyncOn is set and (SyncSize +1) >= 4.
rw
0x01 5th byte of Sync word.
* Used if SyncOn is set and (SyncSize +1) >= 5.
rw
0x01 6th byte of Sync word.
* Used if SyncOn is set and (SyncSize +1) >= 6.
rw
0x01 7th byte of Sync word.
* Used if SyncOn is set and (SyncSize +1) >= 7.
rw
0x01 8th byte of Sync word.
* Used if SyncOn is set and (SyncSize +1) = 8.
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: sales@hoperf.com http://www.hoperf.com
Page 62