English
Language : 

RF65 Datasheet, PDF (35/72 Pages) List of Unclassifed Manufacturers – Low Power Integrated UHF Receiver With -120dBm High Sensitivity
ADVANCED COMMUNICATIONS & SENSING
Upon detection of a valid packet, the sequencing is altered, as shown below:
PayloadReady
ListenCriteria
passed
ListenEnd = 00
Idle
Rx
Listen Mode
RF65
DATASHEET
ListenEnd = 01
Idle
Rx
Listen Mode
Mode
ListenEnd = 10
Idle
Rx
Listen Mode
Idle
Rx
Figure 18. Listen Mode Sequence (wanted signal is received)
Listen mode can be disabled by writing ListenOn to 0
4.3.4. RC Timer Accuracy
All timings of the Listen Mode rely on the accuracy of the internal low-power RC oscillator. This oscillator is automatically
calibrated at the device power-up, and it is a user-transparent process.
For applications enduring large temperature variations, and for which the power supply is never removed, RC calibration
can be performed upon user request. RcCalStart in RegOsc1 can be used to trigger this calibration, and the flag
RcCalDone will be set automatically when the calibration is over.
Page 35
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: sales@hoperf.com http://www.hoperf.com