RF65 Datasheet, PDF (59/72 Pages) List of Unclassifed Manufacturers – Low Power Integrated UHF Receiver With -120dBm High Sensitivity | |||
|
◁ |
ADVANCED COMMUNICATIONS & SENSING
RF65
DATASHEET
RegOokPeak
(0x1B)
7-6 OokThreshType
5-3 OokPeakTheshStep
2-0 OokPeakThreshDec
RegOokAvg
(0x1C)
7-6 OokAverageThreshFilt
RegOokFix
(0x1D)
RegAfcFei
(0x1E)
5-0 -
7-0 OokFixedThresh
7-
6 FeiDone
5 FeiStart
4 AfcDone
3 AfcAutoclearOn
RegAfcMsb
(0x1F)
RegAfcLsb
(0x20)
RegFeiMsb
(0x21)
RegFeiLsb
(0x22)
RegRssiConfig
(0x23)
RegRssiValue
(0x24)
2 AfcAutoOn
1 AfcClear
0 AfcStart
7-0 AfcValue(15:8)
7-0 AfcValue(7:0)
7-0 FeiValue(15:8)
7-0 FeiValue(7:0)
7-2 -
1 RssiDone
0 RssiStart
7-0 RssiValue
rw
01 Selects type of threshold in the OOK data slicer:
00â fixed
10â average
01â peak
11â reserved
rw
000 Size of each decrement of the RSSI threshold in the OOK
demodulator:
000â 0.5 dB
001â 1.0 dB
010â 1.5 dB
011â 2.0 dB
100â 3.0 dB
101â 4.0 dB
110â 5.0 dB
111â 6.0 dB
rw
000 Period of decrement of the RSSI threshold in the OOK
demodulator:
000â once per chip
001â once every 2 chips
010â once every 4 chips 011â once every 8 chips
100â twice in each chip 101â 4 times in each chip
110â 8 times in each chip 111â 16 times in each chip
rw
10 Filter coefficients in average mode of the OOK
demodulator:
00â fC â chip rate / 32.Ï
01â fC â chip rate / 8.Ï
10â fC â chip rate / 4.Ï
11â fC â chip rate / 2.Ï
r 000000 unused
rw
0110 Fixed threshold value (in dB) in the OOK demodulator.
(6dB) Used when OokThresType = 00
r
0 unused
r
0 0â FEI is on-going
1â FEI finished
w
0 Triggers a FEI measurement when set. Always reads 0.
r
1 0â AFC is on-going
1â AFC has finished
rw
0 Only valid if AfcAutoOn is set
0â AFC register is not cleared before a new AFC phase
1â AFC register is cleared before a new AFC phase
rw
0 0â AFC is performed each time AfcStart is set
1â AFC is performed each time Rx mode is entered
w
0 Clears the AfcValue if set in Rx mode. Always reads 0
w
0 Triggers an AFC when set. Always reads 0.
r
0x00 MSB of the AfcValue, 2âs complement format
r
0x00 LSB of the AfcValue, 2âs complement format
Frequency correction = AfcValue x Fstep
r
- MSB of the measured frequency offset, 2âs complement
r
- LSB of the measured frequency offset, 2âs complement
Frequency error = FeiValue x Fstep
r 000000 unused
r
1 0â RSSI is on-going
1â RSSI sampling is finished, result available
w
0 Trigger a RSSI measurement when set. Always reads 0.
r
0xFF Absolute value of the RSSI in dBm, 0.5dB steps.
RSSI = -RssiValue/2 [dBm]
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: sales@hoperf.com http://www.hoperf.com