NOTES:
1. VTEST = open for tPLH, tPHL, tPHZ, and tPZH. VTEST = 2 x VCC for tPLZ and tPZL.
2. CL = 50 pF or equivalent (includes test jig and probe capacitance).
3. RL = 500Ω or equivalent.
4. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output
control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the
output control.
5. Input signal from pulse generator: VIN = 0.0 V to VCC; PRR ≤ 1 MHz; ZO = 50Ω; tr ≤ 3.0 ns; tf ≤ 3.0 ns; tr and tf shall be
measured from 10% of VCC to 90% of VCC and from 90% of VCC to 10% of VCC, respectively; duty cycle = 50 percent.
6. Timing parameters shall be tested at a minimum input frequency of 1MHz.
7. The outputs are measured one at a time with one transition per measurement.
FIGURE 5. Switching waveforms and test circuit.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
A
REVISION LEVEL
K
5962-87552
SHEET
15