RHFAC244D03V Datasheet, PDF (10/27 Pages) List of Unclassifed Manufacturers – DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990
TABLE IA. Electrical performance characteristics - Continued.
Test and
MIL-STD-883
test method 1/
Symbol
Test conditions 2/ 3/
-55°C ≤ TC ≤ +125°C
+3.0 V ≤ VCC ≤ +5.5 V
unless otherwise specified
Propagation delay
time, output
enable, mOE
to mYn
3003
tPZH CL = 50 pF
10/ RL = 500Ω
See figure 5
tPZL
10/
Device
type
and
device
class
01
All
02
All
01
All
02
All
01
All
02
All
01
All
02
All
01
All
02
All
01
All
02
All
01
All
02
All
01
All
02
All
VCC
3.0 V
4.5 V
3.0 V
4.5 V
Group A
subgroups
9
10, 11
9
10, 11
9
10, 11
9
10, 11
Limits 4/
Unit
Min Max
1.0 10.5 ns
1.0 10.7
1.0 11.5
1.0 12.9
1.0
7.5
1.0
7.7
1.0
9.0
1.0
9.3
1.0 11.0
1.0 10.6
1.0 13.0
1.0 12.9
1.0
8.5
1.0
7.6
1.0 10.5
1.0
9.1
1/ For tests not listed in the referenced MIL-STD-883, [e.g. VIH, VIL], utilize the general test procedure under the conditions
listed herein.
2/ Each input/output, as applicable, shall be tested at the specified temperature, for the specified limits, to the tests in table
IA herein. Output terminals not designated shall be high level logic, low level logic, or open, except as follows:
a. VIC (pos) tests, the GND terminal can be open. TC = +25°C.
b. VIC (neg) tests, the VCC terminal shall be open. TC = +25°C.
c. All ICC tests, the output terminal shall be open. When performing these tests, the current meter shall be
placed in the circuit such that all current flows through the meter.
3/ RHA parts for device type 01 of this drawing have been characterized through all levels M, D, P, L, R, and F of
irradiation. However, these devices are only tested at the 'F' level. Pre and post irradiation values are identical unless
otherwise specified in table IA. When performing post irradiation electrical measurements for any RHA level, TA = +25°C.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
A
REVISION LEVEL
K
5962-87552
SHEET
10