English
Language : 

RFM69W Datasheet, PDF (11/78 Pages) List of Unclassifed Manufacturers – ISM TRANSCEIVER MODULE
2. Electrical Characteristics
RFM69W
2.2. Absolute Maximum Ratings
Stresses above the values listed below may cause permanent device failure. Exposure to absolute maximum ratings for
extended periods may affect device reliability.
Table 2 Absolute Maximum Ratings
Symbol
VDDmr
Tmr
Tj
Pmr
DC_13dBm
VSWR_13dBm
Description
Supply Voltage
Temperature
Junction temperature
RF Input Level
Duty Cycle of transmission at +13dBm output
Maximum VSWR at antenna port
Min
Max
Unit
-0.5
3.9
V
-55
+115
°C
-
+125
°C
-
+6
dBm
-
1
%
-
3:1
-
2.3. Operating Range
Table 3 Operating Range
Symbol
VDDop
Top
Clop
ML
Description
Supply voltage
Operational temperature range
Load capacitance on digital ports
RF Input Level
Min
Max
Unit
1.8
3.6
V
-40
+85
°C
-
25
pF
-
0
dBm
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: sales@hoperf.com http:/ / www.hoperf.com
Page 11