7.9. Quad Output Fast Read (6BH)
http://www.elm-tech.com
The Quad Output Fast Read command is followed by 3-byte address (A23-A0) and a dummy byte, each bit
being latched in during the rising edge of SCLK, then the memory contents are shifted out 4-bit per clock cycle
from IO3, IO2, IO1 and IO0. The command sequence is shown in followed Figure10. The first byte addressed
can be at any location. The address is automatically incremented to the next higher address after each byte of
data is shifted out.
Figure 10. Quad Output Fast Read Sequence Diagram
CS#
SCLK
0 1 2 3 4 5 6 7 8 9 10
28 29 30 31
SI(IO0)
SO(IO1)
WP#(IO2)
HOLD#(IO3)
Command
6BH
24-bit address
23 22 21
3210
High-Z
High-Z
High-Z
CS#
SCLK
SI(IO0)
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
Dummy Clocks
40404040 4
SO(IO1)
515151515
WP#(IO2)
626262626
HOLD#(IO3)
737373737
Byte1 Byte2 Byte3 Byte4
7.10. Dual I/O Fast Read (BBH)
The Dual I/O Fast Read command is similar to the Dual Output Fast Read command but with the capability
to input the 3-byte address (A23-0) and a “Continuous Read Mode” byte 2-bit per clock by SI and SO, each bit
being latched in during the rising edge of SCLK, then the memory contents are shifted out 2-bit per clock cycle
from SI and SO. The command sequence is shown in followed Figure11. The first byte addressed can be at any
location. The address is automatically incremented to the next higher address after each byte of data is shifted
out.
Dual I/O Fast Read with “Continuous Read Mode”
The Dual I/O Fast Read command can further reduce command overhead through setting the “Continuous
Read Mode” bits (M7-0) after the input 3-byte address (A23-A0). If the “Continuous Read Mode” bits (M7-0)
=AXH, then the next Dual I/O Fast Read command (after CS# is raised and then lowered) does not require the
BBH command code. The command sequence is shown in followed Figure12. If the “Continuous Read Mode”
bits (M7-0) are any value other than AXH, the next command requires the first BBH command code, thus
returning to normal operation. A “Continuous Read Mode” Reset command can be used to reset (M7-0)
before issuing normal command.