English
Language : 

DRM-24V80W1PN Datasheet, PDF (6/20 Pages) Delta Electronics, Inc. – Built-in active PFC and up to 90% efficiency
TECHNICAL DATASHEET
CliQ M DIN Rail Power Supply
24V 81.6W 1 Phase / DRM-24V80W1PN
Protections
Overvoltage
Overload / Overcurrent
Over Temperature
Short Circuit
Transient Surge Voltage Protection
Internal Fuse
Degree of Protection
Protection Against Shock
*PE: Primary Earth
28.8 – 35.2V, SELV Output,
Hiccup Mode, Non-Latching
(Auto-Recovery)
Refer to the details in the Function
section
> 150% of rated load current,
Constant current limit, Auto-
Recovery when the fault is
removed
Refer to the details in the Function
section
< 80°C Surrounding Air
Refer to the details in the Function
Temperature @ 100% load, section
Non-Latching (Auto-Recovery)
Hiccup Mode, Non-Latching Load impedance ≤ 100mOhm, refer to
(Auto-Recovery when the fault the details in the Function section
is removed)
MOV (Metal Oxide Varistor)
T3.15A
IP20
Class I with PE* connection
Reliability Data
MTBF (as per Telcordia SR-332)
2,164,300 hrs.
1,341,200 hrs.
I/P: 100Vac, O/P: 24V, 3.4A, Ta: 25°C
I/P: 100Vac, O/P: 24V, 3.4A, Ta: 40°C
Expected Cap Life Time**
100Vac
230Vac
131,400hrs.
131,400hrs.
131,400hrs.
O/P: 24V, 3.4A, Ta: 25°C
O/P: 24V, 3.4A, Ta: 40°C
O/P: 24V, 1.7A, Ta: 40°C
**Estimated lifetime when 24 hours operating a day and E-cap’s manufacturer guarantee at 131,400 hrs (15 years) as maximum limit of lifetime.
6
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (May 2016, Rev. 00)