DRM-24V80W1PN Datasheet, PDF (5/20 Pages) Delta Electronics, Inc. – Built-in active PFC and up to 90% efficiency
TECHNICAL DATASHEET
CliQ M DIN Rail Power Supply
24V 81.6W 1 Phase / DRM-24V80W1PN
Mechanical
Case Cover / Chassis
Dimensions (L x W x D)
Unit Weight
Indicator
Cooling System
Terminal
Wire
Mounting Rail
Noise (1 Meter from power supply)
Environment
Surrounding Air Temperature
Power De-rating
Operating Humidity
Operating Altitude
Shock Test (Non-Operating)
Vibration (Non-Operating)
Bump Test (Operating)
Over Voltage Category
Pollution Degree
Input
Output
Input
Output
Aluminium
124 x 32 x 102 mm (4.88 x 1.26 x 4.02 inch)
0.50 kg (1.10 lb)
Green LED (DC OK) and Red LED (Overload)
Convection
3 Pins (Rated 600V/35A)
6 Pins (Rated 300V/8A)
AWG 20-8
AWG 22-16
Standard TS35 DIN Rail in accordance with EN 60715
Sound Pressure Level (SPL) < 25dBA
Operating -25°C to +70°C (Cold start -40°C)
Storage -40°C to +85°C
Vertical
Mounting
Horizontal
Mounting
> 60°C de-rate power by 2.5% / °C
> 50°C de-rate power by 2.5% / °C
5 to 95% RH (Non-Condensing)
0 to 5,000 Meters (16,400 ft.) for ITE application
0 to 2,500 Meters (8,200 ft.) for Industrial application
IEC60068-2-27, Half Sine Wave: 30G for a duration of 18ms;
3 times per direction, 6 times in total
IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of
0.35mm; 60 min per axis for all X, Y, Z directions
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms,
1,000 times per direction, 6,000 times in total
III
According to EN 50178 / EN 60204-1
(clearance and creepage distances) and
IEC 62103 (safety part)
2
5
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.