DS1780 Datasheet, PDF (17/28 Pages) Dallas Semiconductor – CPU Peripheral Monitor
DS1780
CONFIGURATION REGISTER (ADDRESS 0X40; POWER-UP DEFAULT = 08h)
Table 10.2
BIT NAME R/W
DESCRIPTION
Logic 1 enables startup of measurement loop, logic 0 places the DS1780 in standby mode.
Caution: The INT output pin will not be cleared if the user writes a 0 to this location after an
0
START
R/W interrupt has occurred (see “ INT Clear” bit). At startup, limit checking functions and
scanning begins. Note, all HIGH and LOW LIMITS should be set into the DS1780 prior to
turning on this bit. (Power-up default=0).
1 INT Enable R/W Logic 1 enables the INT output. 1=Enabled 0=Disabled (Power-up Default = 0)
2
Reserved R/W Power-up Default = 0.
During Interrupt Service Routine (ISR) this bit asserted logic 1 clears INT output without
3
INT Clear R/W affecting the contents of the Interrupt Status Registers. The device will stop monitoring. It
will resume upon clearing of this bit. (Power-up default=1.)
4
RESET
R/W
Creates a RESET (Active Low) signal for 20 ms (min) on the RST output. (Power-up
default = 0) This bit is cleared once the RST pulse goes active.
5
Reserved R/W Power-up Default = 0.
6
CHS Reset
R/W
Logic 1 resets the chassis intrusion pin. (Power-up default = 0) This bit is cleared after CHS
becomes cleared.
Logic 1 restores power-up default values to all DS1780 registers except for the analog
7 Initialization R/W output and value RAM, which remain unchanged. This bit automatically clears itself since
the power on default is 0.
INTERRUPT INT STATUS REGISTER 1 (ADDRESS 0X41; POWER-UP
DEFAULT = 00h) Table 10.3
BIT NAME R/W
DESCRIPTION
0 +2.5V_Error R A 1 indicates a High or Low limit has been exceeded.
1 VCCP1_Errror R A 1 indicates a High or Low limit has been exceeded.
2 +3.3V_Error R A 1 indicates a High or Low limit has been exceeded.
3
+5V_Error
R A 1 indicates a High or Low limit has been exceeded.
A 1 indicates that a high or low temperature limit has been exceeded. The conditions that
4 Temp_Error R will generate and clear this bit depend upon the temperature interrupt mode chosen. The
mode is set at bits 0 and 1 of the Temperature Configuration Register (0x48h).
5
Reserved
R0
6 FAN1_Error R A 1 indicates that a fan count limit has been exceeded.
7 FAN2_Error R A 1 indicates that a fan count limit has been exceeded.
17 of 28