English
Language : 

CPC7595 Datasheet, PDF (8/25 Pages) Clare, Inc. – Line Card Access Switch
CPC7595
1.6.4 TESTout Switches, SW5 and SW6
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
VSW5 (differential) = TLINE to TTESTOUT
VSW6 (differential) = RLINE to RTESTOUT
All-Off state.
+25° C,
VSW (differential) = -320 V to gnd
0.1
Off-State
VSW (differential) = +260 V to -60 V
Leakage Current
+85° C
VSW (differential) = -330 V to gnd
ISW
-
0.3
1
μA
VSW (differential) = +260 V to -60 V
-40° C
VSW (differential) = -310 V to gnd
0.1
VSW (differential) = +250 V to -60 V
ISW (on) = ±10 mA, ±40 mA, +25° C
35
-
On Resistance
DC current limit
Dynamic current limit
(t ≤ 0.5 μs)
Logic input to switch
output isolation
dv/dt sensitivity
ISW (on) = ±10 mA, ±40 mA, +85° C
RON
-
50
70
ISW (on) = ±10 mA, ±40 mA, -40° C
26
-
VSW (on) = ±10 V, +25° C
-
140
-
y VSW (on) = ±10 V, +85° C
ISW
80
100
-
r VSW (on) = ±10 V, -40° C
-
210
250
Test out switches on, all other switches
a off. Apply ±1 kV, 10x1000 μs pulse with
ISW
-
2.5
-
appropriate protection in place.
in VSW5 (TTESTout, TLINE)
VSW6 (RTESTout, RLINE)
+25° C, Logic inputs = gnd,
VSW = ±320 V
0.1
+85° C, Logic inputs = gnd,
lim VSW = ±330 V
ISW
-
0.3
1
-40° C, Logic inputs = gnd,
VSW = ±310 V
0.1
Pre-
-
500
-
Ω
mA
A
μA
V/μs
8
www.clare.com
R00B