1.6 Switch Specifications
1.6.1 Break Switches, SW1 and SW2
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
VSW1 (differential) = TLINE to TBAT
VSW2 (differential) = RLINE to RBAT
All-Off state.
+25° C,
Off-State
Leakage Current
On Resistance
On Resistance
Matching
DC current limit
Dynamic current limit
(t ≤ 0.5 μs)
VSW (differential) = -320 V to gnd
VSW (differential) = +260 V to -60 V
+85° C,
y VSW (differential) = -330 V to gnd
ISW
-
r VSW (differential) = +270 V to -60 V
-40° C,
a VSW (differential) = -310 V to gnd
VSW (differential) = +250 V to -60 V
in ISW(on) = ±10 mA, ±40 mA,
RBAT and TBAT = -2 V
+25° C
+85° C
RON
-
lim -40° C
Per SW1 & SW2 On Resistance test
conditions.
ΔRON
-
VSW (on) = ±10 V, +25° C
-
e VSW (on) = ±10 V, +85° C
ISW
80
r VSW (on) = ±10 V, -40° C
-
Break switches on, all other switches
P off. Apply ±1 kV 10x1000 μs pulse with
ISW
-
0.1
0.3
1
0.1
14.5
-
20.5
28
10.5
-
0.15
0.8
225
-
150
400
425
2.5
-
appropriate protection in place.
μA
Ω
Ω
mA
A
Logic input to switch
output isolation
dv/dt sensitivity
+25° C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±320 V
+85° C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±330 V
-40° C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±310 V
-
-
0.1
ISW
-
0.3
1
μA
-
0.1
-
-
500
-
V/μs