English
Language : 

CPC7595 Datasheet, PDF (3/25 Pages) Clare, Inc. – Line Card Access Switch
1. Specifications
CPC7595
1.1 Package Pinout
1.2 Pinout
FGND 1
NC 2
NC 3
NC 4
TTESTin 5
TBAT 6
TLINE 7
TRINGING 8
NC 9
TTESTout 10
NC 11
VDD 12
TSD 13
DGND 14
FGND 1
T 2 TESTin
TBAT 3
T 4 LINE
T 5 RINGING
T 6 TESTout
NC 7
VDD 8
TSD 9
DGND 10
CPC7595B &
CPC7595M
28 VBAT
20 28
Pin Pin
Name
Description
27 NC
26 NC
25 NC
24 RTESTin
23 RBAT
22 RLINE
21 NC
1
2
3
4
5
1 FGND Fault ground.
2 NC No connection.
3 NC No connection.
y 4 NC No connection.
r 5 TTESTin Tip lead of the TESTin bus.
6 TBAT Tip lead of the SLIC.
a 7 TLINE Tip lead of the line side.
8 TRINGING Ringing generator return.
in9 NC Not connected.
20 RRINGING
19 RTESTout
lim 18 LATCH
17 IN TESTin
16 INRINGING
Pre15 INTESTout
6 10 TTESTout Tip lead of the TESTout bus.
7 11 NC No connection.
8 12 VDD +5 V supply.
9 13 TSD Temperature shutdown pin.
10 14 DGND Digital ground.
11 15 INTESTout Logic control input.
12 16 INRINGING Logic control input.
13 17 INTESTin Logic control input.
14 18 LATCH Data latch enable control input.
15 19 RTESTout Ring lead of the TESTout bus.
CPC7595Z
16 20 RRINGING Ringing generator source.
21 NC No connection.
20 VBAT
19 RTESTin
18 RBAT
17 RLINE
16 RRINGING
17 22
18 23
19 24
25
26
27
RLINE
RBAT
RTESTin
NC
NC
NC
Ring lead of the line side.
Ring lead of the SLIC.
Ring lead of the TESTin bus.
No connection.
No connection.
No connection.
15 RTESTout
20 28 VBAT Battery supply.
14 LATCH
13 INTESTin
12 INRINGING
11 INTESTout
R00B
www.clare.com
3