1.8 Voltage and Power Specifications
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
Voltage Requirements
VDD
-
VDD
4.5
5.0
5.5
V
VBAT1
-
VBAT
-19
-48
-72
V
1VBAT is used only for internal protection circuitry. If VBAT rises above-10 V, the device will enter the all-off state and will remain in the all-off state until the battery
drops below -15 V
Power Specifications
VDD = 5 V, VBAT = -48 V, VIH = 2.4V,
y Power consumption
VIL = 0.4V, Measure IDD and IBAT,
Talk and All-Off States
P
-
4.7
10.5
r All other states
P
-
5.2
10.5
VDD current in talk and
a all-off states
VDD = 5 V, VBAT = -48 V, VIH = 2.4V,
IDD
-
0.9
2.0
VDD current in all other VIL = 0.4V
in states
IDD
-
1.0
2.0
VBAT
current in
any
state
VDD = 5V, VBAT
VIL = 0.4V
=
-48
V,
VIH
=
2.4V,
IBAT
-
4
10
lim 1.9 Protection Circuitry Electrical Specifications
Parameter
Conditions
Protection Diode Bridge
e Forward Voltage drop,
continuous current
r (50/60 Hz)
Apply ± dc current limit of break
switches
Forward Voltage drop, Apply ± dynamic current limit of break
P surge current
switches
Symbol
VF
VF
Minimum
-
-
Typical
2.8
5
Maximum
3.5
-
mW
mW
mA
μA
Unit
V
Optional Protection SCR
Surge current
-
-
-
-
*
A
Trigger current:
SCR activates, +25° C
Current into VBAT pin. SCR activates, +85° C
ITRIG
-
150
80
-
mA
Hold current: Current SCR remains active, +25° C
through protection SCR SCR remains active, +85° C
-
220
IHOLD
110
145
-
mA
Gate trigger voltage IGATE = ITRIGGER§
VTBAT or
VRBAT
VBAT -4
-
VBAT -2
V
Reverse leakage current VBAT = -48 V
IVBAT
-
-
1.0
μA
On-state voltage
0.5 A, t = 0.5 μs
2.0 A, t = 0.5 μs
VTBAT or
VRBAT
-
-3
-5
-
V
Temperature Shutdown Specifications
Shutdown activation
temperature
Not production tested - limits are
TTSD_on
110
125
150
°C
guaranteed by design and Quality
Shutdown circuit
hysteresis
Control sampling audits.
TTSD_off
10
-
25
°C
*Passes GR1089 and ITU-T K.20 with appropriate secondary protection in place.
§VBAT must be capable of sourcing ITRIGGER for the internal SCR to activate.
R00B
www.clare.com