English
Language : 

CPC7595 Datasheet, PDF (6/25 Pages) Clare, Inc. – Line Card Access Switch
CPC7595
1.6.2 Ringing Return Switch, SW3
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
VSW3 (differential) = TLINE to TRINGING
All-Off state.
+25° C,
VSW (differential) = -320 V to gnd
0.1
Off-State
VSW (differential) = +260 V to -60 V
Leakage Current
+85° C,
VSW (differential) = -330 V to gnd
ISW
-
0.3
1
μA
VSW (differential) = +270 V to -60 V
-40° C,
VSW (differential) = -310 V to gnd
0.1
VSW (differential) = +250 V to -60 V
ISW(on) = ±0 mA, ±10 mA, +25° C
60
-
On Resistance
ISW(on) = ±0 mA, ±10 mA, +85° C
RON
-
85
110
Ω
DC current limit
Dynamic current limit
(t ≤ 0.5 μs)
Logic input to switch
output isolation
dv/dt sensitivity
ISW(on) = ±0 mA, ±10 mA, -40° C
45
-
VSW (on) = ± 10 V, +25° C
-
120
VSW (on) = ± 10 V, +85° C
ISW
70
85
-
y VSW (on) = ± 10 V, -40° C
-
210
r Ringing switches on, all other switches
off. Apply ±1 kV 10x1000 μs pulse with
ISW
-
2.5
-
a appropriate protection in place.
+25° C, Logic inputs = gnd,
in VSW (TRINGING, TLINE) = ±320 V
0.1
+85° C, Logic inputs = gnd,
VSW (TRINGING, TLINE) = ±330 V
ISW
-
0.3
1
-40° C, Logic inputs = gnd,
VSW (TRINGING, TLINE) = ±310 V
0.1
Prelim -
-
-
500
-
mA
A
μA
V/μs
6
www.clare.com
R00B