English
Language : 

HCPL-7710-000E Datasheet, PDF (6/18 Pages) AVAGO TECHNOLOGIES LIMITED – 40 ns Propagation Delay, CMOS Optocoupler
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option 060)
        
Description
Symbol
Installation classification per DIN VDE 0110/1.89, Table 1
  for rated mains voltage ≤150 V rms
  for rated mains voltage ≤300 V rms
  for rated mains voltage ≤450 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b†
  VIORM x 1.875 = VPR, 100% Production
  Test with tm = 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a†
  VIORM x 1.5 = VPR, Type and Sample Test,
  tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage†
(Transient Overvoltage, tini = 10 sec)
Safety Limiting Values
  (Maximum values allowed in the event of a failure,
  also see Thermal Derating curve, Figure 11.)
   Case Temperature
   Input Current
   Output Power
Insulation Resistance at TS, V10 = 500 V
VIORM
VPR
VPR
VIOTM
TS
IS,INPUT
PS,OUTPUT
RIO
HCPL-7710
Option 060
HCPL-0710
Option 060 Units
I-IV
I-IV
I-IV
I-III
I-III
55/100/21
55/100/21
2
2
630
560
V peak
1181
1050
V peak
945
840
V peak
6000
4000
V peak
175
230
600
≥109
150
°C
150
mA
600
mW
≥109
Ω
†Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations sec-
tion IEC/EN/DIN EN 60747-5-2, for a detailed description.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be
ensured by means of protective circuits.
Note: The surface mount classification is Class A in accordance with CECC 00802.
Absolute Maximum Ratings
Parameter
Storage Temperature
Ambient Operating Temperature
Supply Voltages
Input Voltage
Output Voltage
Input Current
Average Output Current
Lead Solder Temperature
Solder Reflow Temperature Profile
Symbol
Min.
Max.
Units
TS
–55
125
°C
TA
–40
+100
°C
VDD1, VDD2
0
6.0
Volts
VI
–0.5
VDD1 +0.5 Volts
VO
–0.5
VDD2 +0.5 Volts
II
–10
+10
mA
IO
10
mA
260°C for 10 sec., 1.6 mm below seating plane
See Solder Reflow Temperature Profile Section
Recommended Operating Conditions
Parameter
Ambient Operating Temperature
Supply Voltages
Logic High Input Voltage
Logic Low Input Voltage
Input Signal Rise and Fall Times

Symbol
Min.
TA
–40
VDD1, VDD2 4.5
VIH
2.0
VIL
0.0
tr, tf
Max.
Units
+100
°C
5.5
V
VDD1
V
0.8
V
1.0
ms