Insulation and Safety Related Specifications
Parameter
Symbol
Value
Minimum External L(101)
7.1
Air Gap (External
Clearance)
Minimum External L(102)
7.4
Tracking (External
Creepage)
Minimum Internal
0.08
Plastic Gap
(Internal Clearance)
Minimum Internal
NA
Tracking (Internal
Creepage)
Tracking Resistance CTI
200
(Comparative
Tracking Index)
Isolation Group
IIIa
8-Pin DIP
(300 Mil) SO-8
Value Units
4.9
mm
4.8
mm
0.08 mm
NA
mm
200 Volts
IIIa
Conditions
Measured from input terminals to output to
to output terminals, shortest distance through
air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance, conductor to
conductor, usually the direct distance
between the photoemitter and photodetector
inside the optocoupler cavity.
Measured from input terminals to output
terminals, along internal cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Option 300 - surface mount classification is Class A in accordance with CECC 00802.