Slow IGBT Gate Discharge During Fault Condition
When a desaturation fault is detected, a weak pull-down
device in the HCPL-316J output drive stage will turn on
to ‘softly’ turn off the IGBT. This device slowly discharges
the IGBT gate to prevent fast changes in drain current
that could cause damaging voltage spikes due to lead
and wire inductance. During the slow turn off, the large
output pull-down device remains off until the output
voltage falls below VEE + 2 Volts, at which time the large
pull down device clamps the IGBT gate to VEE.
DESAT Fault Detection Blanking Time
The DESAT fault detection circuitry must remain disabled
for a short time period following the turn-on of the IGBT
to allow the collector voltage to fall below the DESAT
theshold. This time period, called the DESAT blanking
time, is controlled by the internal DESAT charge current,
the DESAT voltage threshold, and the external DESAT ca-
pacitor. The nominal blanking time is calculated in terms
of external capacitance (CBLANK), FAULT threshold volt-
age (VDESAT), and DESAT charge current (ICHG) as tBLANK
= CBLANK x VDESAT / ICHG. The nominal blanking time
with the recommended 100 pF capacitor is 100 pF * 7 V
/ 250 μA = 2.8 μsec. The capacitance value can be scaled
slightly to adjust the blanking time, though a value small-
er than 100 pF is not recommended. This nominal blank-
ing time also represents the longest time it will take for
the HCPL-316J to respond to a DESAT fault condition. If
the IGBT is turned on while the collector and emitter are
shorted to the supply rails (switching into a short), the
soft shut-down sequence will begin after approximately
3 μsec. If the IGBT collector and emitter are shorted to
the supply rails after the IGBT is already on, the response
time will be much quicker due to the parasitic parallel
capacitance of the DESAT diode. The recommended 100
pF capacitor should provide adequate blanking as well
as fault response times for most applications.
Under Voltage Lockout
The HCPL-316J Under Voltage Lockout (UVLO) feature is
designed to prevent the application of insufficient gate
voltage to the IGBT by forcing the HCPL-316J output low
during power-up. IGBTs typically require gate voltages
of 15 V to achieve their rated VCE(ON) voltage. At gate
voltages below 13 V typically, their on-voltage increases
dramatically, especially at higher currents. At very low
gate voltages (below 10 V), the IGBT may operate in the
linear region and quickly overheat. The UVLO function
causes the output to be clamped whenever insufficient
operating supply (VCC2) is applied. Once VCC2 exceeds
VUVLO+ (the positive-going UVLO threshold), the UVLO
clamp is released to allow the device output to turn on
in response to input signals. As VCC2 is increased from 0 V
(at some level below VUVLO+), first the DESAT protection
circuitry becomes active. As VCC2 is further increased
(above VUVLO+), the UVLO clamp is released. Before the
time the UVLO clamp is released, the DESAT protection
is already active. Therefore, the UVLO and DESAT FAULT
DETECTION features work together to provide seamless
protection regardless of supply voltage (VCC2).